[Home ] [Archive]    
:: Main :: About :: Current Issue :: Archive :: Search :: Submit :: Contact ::
:: Volume 11, Issue 4 (10-2013) ::
Int J Radiat Res 2013, 11(4): 215-224 Back to browse issues page
Small photon field dosimetry using EBT2 Gafchromic film and Monte Carlo simulation
M. Yarahmadi , H.A. Nedaie Dr. , M. Allahverdi , Kh. Asnaashari , O.A. Sauer
Department of Medical Physics , Faculty of Medicine, Tehran University of Medical Sciences, Tehran, Iran , nedaieha@sina.tums.ac.ir
Abstract:   (8252 Views)

Background: Small photon fields are increasingly used in modern radiotherapy especially in intensity modulated radiation therapy (IMRT) and stereotactic radiosurgery (SRS) treatments. Accurate beam profile and central axis depth doses measurements of such beams are complicated due to the electron disequilibrium. Hence the EBT2 (external beam therapy) Gafchromic film was used for dosimetry of small circular photon beams because of its high spatial resolution. The results of EBT2 film were compared with PinPoint measurements and Monte Carlo calculations. Materials and Methods: Four small field sizes (5, 10, 20 and 30 mm diameters) were produced by circular cones coupled to a Varian Clinac-2100 linear accelerator at 6MV photon beam energy. Experimental measurements were carried out using two dosimeters: The Gafchromic EBT2 film and the 0.015 cm3 PinPoint ionization chamber (PTW, type 31006). The EGSnrc/BEAMnrc code was used to calculate dosimetric parameters for the above small fields. Results: The results showed that the PDD values measured by EBT2 film had maximum local differences 4% and 3% with PinPoint measurements and MC calculations respectively. The measurements of penumbra (80-20%) at 5 cm depth in a water phantom and SSD=100 cm by EBT2 film were up to 0.8 and 0.4 mm smaller than PinPoint measurements and MC calculation respectively. Our results show good agreement between EBT2 film measurements and MC calculation for small field output factors but PinPoint measurements need correction factors. Conclusion: This study showed that the Gafchromic EBT2 film is suitable detector for small field dosimetry especially for penumbra and output factor measurements.

Keywords: Small field, dosimetry, Gafchromic EBT2 film, Monte Carlo
Full-Text [PDF 547 kb]   (2403 Downloads)    
Type of Study: Original Research | Subject: Medical Physics
Send email to the article author

Add your comments about this article
Your username or Email:

CAPTCHA code


XML     Print


Download citation:
BibTeX | RIS | EndNote | Medlars | ProCite | Reference Manager | RefWorks
Send citation to:

Yarahmadi M, Nedaie H, Allahverdi M, Asnaashari K, Sauer O. Small photon field dosimetry using EBT2 Gafchromic film and Monte Carlo simulation. Int J Radiat Res. 2013; 11 (4) :215-224
URL: http://ijrr.com/article-1-1101-en.html


Volume 11, Issue 4 (10-2013) Back to browse issues page
International Journal of Radiation Research
Persian site map - English site map - Created in 0.05 seconds with 32 queries by YEKTAWEB 3742