Evaluation of changes in excision cavity volume during whole breast irradiation using secondary CT image
A.R. Nikoofar , Z. Falahatpour Dr. , G.H. Hoseinzadeh
Medical Radiation Engineering of Faculty of Shahid Beheshti University, Tehran, Iran , mahsa_falahat@yahoo.com
Abstract:   (3155 Views)

Background: The aim of this study was to evaluate the reduction in excision cavity volume (ECV) during the whole breast radiotherapy (WBRT). The delineating of reduced cavity volume on secondary CT (computed tomography) might decrease the field size of boost plan. Materials and Methods: Twenty patients were treated having breast conservative surgery. At first, primary CT simulation (CT-1) was done prior to WBRT. Treatment planning was performed by a 3D treatment planning system. A CT-2 was performed after WBRT. Then the excision cavity was contoured on CT-1 and CT-2 for each patient. Boost irradiation was planned on both ECV-1 and ECV-2. Results: In Comparison of CT-1 and CT-2: The contoured volumes for ECV-1 and ECV-2 were on average of 42.9 cm3and 23.4 cm3, respectively (p< 0.002). The ECV-2 was reduced in 85% of the patients. Patients with ECV-1 greater than the mean value of ECV-1 (ECV-1> 35.5 cm3) had more reduction in ECV-2 than patient with ECV-1 smaller than the mean value (p < 0.000). The volume of normal breast tissue on CT-2 was decreased from the volume of CT-1 (p< 0.03). Conclusion: A significant reduction in excision cavity volume was shown during WBRT. This volume reduction made smaller sizes of boost field and remaining breast received lower doses. The reduction was more significant in patient with primary large ECV. The Secondary CT for boost planning is suggested for patients with larger cavities after WBRT.

Keywords: Excision cavity volume (ECV), secondary CT, whole breast radiotherapy (WBRT)
Full-Text [PDF 632 kb]   (828 Downloads)    
Type of Study: Original Research | Subject: Medical Physics
Send email to the article author

Add your comments about this article
Your username or Email:

Write the security code in the box >


XML     Print


Download citation:
BibTeX | RIS | EndNote | Medlars | ProCite | Reference Manager | RefWorks
Send citation to:

Nikoofar A, Falahatpour Z, Hoseinzadeh G. Evaluation of changes in excision cavity volume during whole breast irradiation using secondary CT image. Int J Radiat Res. 2014; 12 (3) :243-248
URL: http://ijrr.com/article-1-1282-en.html


Volume 12, Issue 3 (7-2014) Back to browse issues page
International Journal of Radiation Research
Persian site map - English site map - Created in 0.07 seconds with 32 queries by YEKTAWEB 3705