[Home ] [Archive]    
:: Main :: About :: Current Issue :: Archive :: Search :: Submit :: Contact ::
Main Menu
Home::
IJRR Information::
For Authors::
For Reviewers::
Subscription::
News & Events::
Web Mail::
::
Search in website

Advanced Search
..
Receive site information
Enter your Email in the following box to receive the site news and information.
..
ISSN
Hard Copy 2322-3243
Online 2345-4229
..
Online Submission
Now you can send your articles to IJRR office using the article submission system.
..

AWT IMAGE

AWT IMAGE

:: Volume 15, Issue 1 (1-2017) ::
Int J Radiat Res 2017, 15(1): 123-128 Back to browse issues page
Application of FLUKA code to gamma-ray attenuation, energy deposition and dose calculations
N. Demir , U. Akar Tarim , O. Gurler
Physics Department, Faculty of Arts and Sciences, Uludag University, Gorukle Campus,16059, Bursa, Turkey
Abstract:   (7452 Views)

Background: In radiation therapy, water is the phantom material of choice, both for reference and for relative dosimetry measurements. Solid phantoms, however, are more useful for routine measurements because they tend to be more robust and easier to set up than water phantoms. Materials and Methods: FLUKA input data cards have been arranged in sequential order. A simple cylindrical geometry with the axis along the z-direction was described in the input file. A beam of 1x105 gamma-rays was directed towards the materials in the z-direction. The results of photon transmission, I/I0, were obtained from output files for each of the material thicknesses using the USRBDX score card. The USRBIN score card was also included in the input file, and the energy deposited by 661.6 keV photons into water and solid phantom materials has been obtained. Results: The values of linear attenuation coefficients calculated by FLUKA are closer to experimentally obtained ones. The values of the linear attenuation coefficients derived from XCOM are greater than those derived from the FLUKA transmission data. The values of dose absorbed in Perspex are smaller than those of other materials, which are closer to each other.  Conclusion: RMI-457, plastic water and RW solid phantoms can be used for radiation dosimetry of photons in the energy range from 59.5 to 1332.5 keV. From the investigation of absorbed dose values versus thickness of absorber, Perspex is not a suitable equivalent to water for the tested energies.

Keywords: Gamma-ray, Monte Carlo, radiation dose, radiation shielding, solid phantom.
Full-Text [PDF 894 kb]   (3065 Downloads)    
Type of Study: Short Report | Subject: Radiation Biology
Add your comments about this article
Your username or Email:

CAPTCHA



XML     Print


Download citation:
BibTeX | RIS | EndNote | Medlars | ProCite | Reference Manager | RefWorks
Send citation to:

Demir N, Akar Tarim U, Gurler O. Application of FLUKA code to gamma-ray attenuation, energy deposition and dose calculations . Int J Radiat Res 2017; 15 (1) :123-128
URL: http://ijrr.com/article-1-1895-en.html


Rights and permissions
Creative Commons License This work is licensed under a Creative Commons Attribution-NonCommercial 4.0 International License.
Volume 15, Issue 1 (1-2017) Back to browse issues page
International Journal of Radiation Research
Persian site map - English site map - Created in 0.05 seconds with 50 queries by YEKTAWEB 4645