Int J Radiat Res 2017, 15(4): 383-390 Back to browse issues page
A TLD based method to estimate bowtie filter shape in PET/CT
N. Ahmadi , M.N.  Nasrabadi , A. Karimian , A. Rahmim
Department of Biomedical Engineering, University of Isfahan, Isfahan, Iran , karimian@eng.ui.ac.ir
Abstract:   (5688 Views)
Background: In CT systems, the machine utilizes a bowtie filter to shape the X-ray beam and remove lower energy photons. The shape of this bowtie filter is complicated and its geometry is often not available in detail. These renders the CT dose index (CTDI) to have different values in measurement versus Monte Carlo simulation studies and other analytical calculations especially in dosimetry of internal organs. In existing literature, the bowtie filter shape is extracted by using expensive sensors Materials and Methods: In the present work, the shape of the bowtie filter of the Biograph 6 PET/CT was derived by using Thermolumenecence dosimeters (TLDs). Subsequently, to evaluate the accuracy of the body bowtie filter shape as generated by TLDs, Monte Carlo simulation of CT was performed. 16 X-ray sources in various angles were used within the Monte Carlo code (MCNP-4C) to simulate the CT section of the PET-CT Biograph 6 system and to calculate dose.  Results: The relative difference between simulated and measured CTDI value for the PET/CT Siemens Biograph 6 at 80, 110 and 130 kVp were 4.2, 2.9 and 2.3%, respectively. Conclusion: In this study, we demonstrate that it is possible to calculate the bowtie filter shape by using an inexpensive TLD method. The results showed that it is possible to determine the shape of the bowtie filter in PET/CT using TLDs with acceptable accuracy.
 
Keywords: PET/CT, bowtie filter, TLD dosimeter, dosimetry.
Full-Text [PDF 811 kb]   (1847 Downloads)    
Type of Study: Original Research | Subject: Radiation Biology
Send email to the article author

Add your comments about this article
Your username or Email:

CAPTCHA



XML     Print


Download citation:
BibTeX | RIS | EndNote | Medlars | ProCite | Reference Manager | RefWorks
Send citation to:

Ahmadi N, Nasrabadi M, Karimian A, Rahmim A. A TLD based method to estimate bowtie filter shape in PET/CT. Int J Radiat Res 2017; 15 (4) :383-390
URL: http://ijrr.com/article-1-2105-en.html


Rights and permissions
Creative Commons License This work is licensed under a Creative Commons Attribution-NonCommercial 4.0 International License.
Volume 15, Issue 4 (10-2017) Back to browse issues page
International Journal of Radiation Research
Persian site map - English site map - Created in 0.04 seconds with 50 queries by YEKTAWEB 4710