:: Volume 16, Issue 4 (10-2018) ::
Int J Radiat Res 2018, 16(4): 493-497 Back to browse issues page
Dosimetric verification of pre-treatment intensity modulated radiation therapy in the commissioning process
G. Esmaili , S.R. Mahdavi , A.R. Nikoofar , P. Fadavi , A. Ameri , V. Nazari
Radiation Biology Research Center & Medical Physics Department, Faculty of Medicine, Iran University of Medical Sciences, Tehran, Iran , mahdavi.r@iums.ac.ir
Abstract:   (3293 Views)
Background: Commissioning tests are recommended before implementing Intensity Modulated Radiation Therapy. This study evaluated five different plans of IMRT mocks for different modulation indices. Materials and Methods: IMRT tests were done in slab phantom for both 6MV and 15 MV photon energies using a 2D array ion chamber dosimeter. Results: The acceptance criteria were based on 3% /3mm. All tests passed the gamma criteria except for the prostate test with 15 MV photon beams and C shape test for both 6 MV and 15 MV energies. The Ratio passing points for Multi target test in 6 MV and 15 MV plans were 93.1% and 91.5%, respectively. The results of the prostate tests with 3%/3mm was 92.3% for 6MV and 91.2% for 15 MV in 4%/4 mm tolerance limit. For Head and Neck test with the same gamma criteria, the percentages of the points were 93.2 and 94 for 6 MV and 15 MV plans, respectively. For C shape tests, the used gamma criteria were 4%/ 4 mm. The ratio passing points were 94.9% and 94.3% for 6MV and 15MV plans, respectively. However, C shape hard test could not pass the gamma criteria of 4%/ 4mm for 6MV. Conclusion: results showed that by increasing the complexity of the IMRT plan, the verification test must be done in a more strict-manner, because a small change in dose delivery can cause a large discrepancy between planned and real dosimetry and may produce hot spots in organs or a cold spot in the target volume.
Keywords: Pre- treatment IMRT, 2D array, IMRT mock, Gamma evaluation.
Full-Text [PDF 1503 kb]   (866 Downloads)    
Type of Study: Technical Note | Subject: Radiation Biology
Send email to the article author

Add your comments about this article
Your username or Email:

CAPTCHA


XML     Print


Download citation:
BibTeX | RIS | EndNote | Medlars | ProCite | Reference Manager | RefWorks
Send citation to:

Esmaili G, Mahdavi S, Nikoofar A, Fadavi P, Ameri A, Nazari V. Dosimetric verification of pre-treatment intensity modulated radiation therapy in the commissioning process . Int J Radiat Res 2018; 16 (4) :493-497
URL: http://ijrr.com/article-1-2403-en.html


Rights and permissions
Creative Commons License This work is licensed under a Creative Commons Attribution-NonCommercial 4.0 International License.
Volume 16, Issue 4 (10-2018) Back to browse issues page
International Journal of Radiation Research
Persian site map - English site map - Created in 0.05 seconds with 50 queries by YEKTAWEB 4645