Determining TG-43 brachytherapy dosimetry parameters and dose distribution for a 131Cs source model CS-1
M. Yazdani , A.A. Mowlavi
, amowlavi@sttu.ac.ir
Abstract:   (13706 Views)
Background: Monte Carlo determination of TG-43 brachytherapy dosimetry parameters and dose distribution calculation for 131Cs source model CS-1 are presented in this study. Materials and Methods: The dose distribution was calculated around the 131Cs Model CS-1 located in the center of 30 cm ×30 cm ×30 cm water, and soft tissue phantoms cube using MCNP code by Monte Carlo method. The percentage depth dose (PDD) variation along the different axis, parallel and perpendicular, the source was calculated. Then, the isodose curves for 100%, 75%, 50% and 25% PDD were constructed. Finally, F(r,|θ|) and g(r) dosimetry parameters of TG-43 protocol have been determined. Results: Results obtained show that the Monte Carlo method could only calculate dose deposition in high gradient region, near the source, accurately. The energy cut off was found to be 1 eV and the error in the calculations was less than 2%. Conclusion: The isodose curves of the CS-1 131Cs source were constructed from dose calculation by MCNP code. The calculated dosimetry parameters for the source were in agreement with previously published results.
Keywords: 131 Cs source, dose distribution, isodose curves, MCNP code.
Full-Text [PDF 457 kb]   (3367 Downloads)    
Type of Study: Original Research | Subject: Radiation Biology
Send email to the article author

Add your comments about this article
Your username or Email:

CAPTCHA


XML     Print


Download citation:
BibTeX | RIS | EndNote | Medlars | ProCite | Reference Manager | RefWorks
Send citation to:

Yazdani M, Mowlavi A. Determining TG-43 brachytherapy dosimetry parameters and dose distribution for a 131Cs source model CS-1. Int J Radiat Res 2007; 5 (2) :85-90
URL: http://ijrr.com/article-1-310-en.html


Rights and permissions
Creative Commons License This work is licensed under a Creative Commons Attribution-NonCommercial 4.0 International License.
Volume 5, Issue 2 (9-2007) Back to browse issues page
International Journal of Radiation Research
Persian site map - English site map - Created in 0.05 seconds with 50 queries by YEKTAWEB 4645