[Home ] [Archive]    
:: Main :: About :: Current Issue :: Archive :: Search :: Submit :: Contact ::
Main Menu
Home::
IJRR Information::
For Authors::
For Reviewers::
Subscription::
News & Events::
Web Mail::
::
Search in website

Advanced Search
..
Receive site information
Enter your Email in the following box to receive the site news and information.
..
ISSN
Hard Copy 2322-3243
Online 2345-4229
..
Online Submission
Now you can send your articles to IJRR office using the article submission system.
..

AWT IMAGE

AWT IMAGE

:: Volume 19, Issue 3 (7-2021) ::
Int J Radiat Res 2021, 19(3): 515-520 Back to browse issues page
The effects of set-up errors on dose distribution in radiotherapy treatment for lung cancer
X. Cao , M. Liu , F. Zhai , N. Li , C. Bao , Y. Liu , G. Chen
Department of Respiratory Medicine, The Third Hospital of Hebei Medical University, Shijiazhuang, Hebei,050017,China , gangchen321@126.com
Abstract:   (2462 Views)
Background: Our aim was to analyze the effects of set-up errors on dose distribution in radiotherapy treatment for lung cancer by using kilovoltage cone-beam CT (CBCT). Materials and Methods: In this study, we used a Varian IX linear accelerator system to perform CBCT scans of 30 lung cancer patients before radiotherapy. Subsequently, the image was matched with the planned CT, and the left and right (LR), top and bottom (SI), and front and back (AP) directions were set incorrectly. And in the CMS planning system, the center of the plan has been moved to the center of the actual scan. Finally, the dose distribution before the bed-moving is simulated. We want to explore the impact of the planned target volume setting error (PTV), the total tumor volume (GTV), and radiation of normal tissues. Results: The set-up errors of the LR, SI and AP directions were (-0.20±2.84), (-1.09±5.40), and (-2.61±2.08) mm, respectively. The 5mm error accounted for 97.8%, 73% and 92.6% in the three directions. Statistically significant differences were found in the distribution of 95%PTV dose, the average dose of PTV, 95% GTV dose and the average dose of GTV without bed-moving, compared with the original plan. Conclusions: In clinical lung cancer radiotherapy, the commonly used setting error is usually less than 5mm, most of which are along the AP direction. In this study, we found that the setting error is related to the patient's inherent characteristics and can significantly change the radiation treatment dose in the target area.
Keywords: Tomography, X-ray computer, cone-beam, set-up error, lung tumor/radiation therapy, dosimetry.
Full-Text [PDF 1501 kb]   (1002 Downloads)    
Type of Study: Original Research | Subject: Radiobiology
Send email to the article author

Add your comments about this article
Your username or Email:

CAPTCHA



XML     Print


Download citation:
BibTeX | RIS | EndNote | Medlars | ProCite | Reference Manager | RefWorks
Send citation to:

Cao X, Liu M, Zhai F, Li N, Bao C, Liu Y et al . The effects of set-up errors on dose distribution in radiotherapy treatment for lung cancer. Int J Radiat Res 2021; 19 (3) :515-520
URL: http://ijrr.com/article-1-3760-en.html


Rights and permissions
Creative Commons License This work is licensed under a Creative Commons Attribution-NonCommercial 4.0 International License.
Volume 19, Issue 3 (7-2021) Back to browse issues page
International Journal of Radiation Research
Persian site map - English site map - Created in 0.05 seconds with 50 queries by YEKTAWEB 4660