[Home ] [Archive]    
:: Main :: About :: Current Issue :: Archive :: Search :: Submit :: Contact ::
Main Menu
Home::
IJRR Information::
For Authors::
For Reviewers::
Subscription::
News & Events::
Web Mail::
::
Search in website

Advanced Search
..
Receive site information
Enter your Email in the following box to receive the site news and information.
..
ISSN
Hard Copy 2322-3243
Online 2345-4229
..
Online Submission
Now you can send your articles to IJRR office using the article submission system.
..

AWT IMAGE

AWT IMAGE

:: Volume 10, Issue 3 And 4 (12-2012) ::
Int J Radiat Res 2012, 10(3 And 4): 151-156 Back to browse issues page
Design of a generally applicable abdominal shield for reducing fetal dose during radiotherapy of common malignancies in pregnant patients
M. Atarod , P. Shokrani , A. Pourmoghadas
, Shokrani@med.mui.ac.ir
Abstract:   (9252 Views)
Background: In most cancer cases, the treatment choice for a pregnant patient is radiotherapy. In these patients, the abdomen is usually not exposed therefore fetus exposure is due to peripheral dose (PD). The purpose of this study was to estimate the fetal dose (the maximum PD in each pregnancy stage) for modalities available and to fabricate and evaluate a generally applicable fetal shield. Materials and Methods: PD values were measured for brain, breast and mediastinum irradiation in a whole body anthropomorphic phantom using a NE 2571 ionization chamber. An external shield was then designed to reduce the fetal dose to the standard dose limit, 5 mSv. Results: The range of PD values as a function of distance from the field’s edge were as follows 1) 9.4-259 cGy for Mantel field 2) 6.5-95 cGy for chest wall irradiation with 10 MeV electrons, 3) 8.5- 52.5 cGy for tangential field with Co-60 and 4) 4.8-7.8 cGy for brain radiotherapy with 9 MV photon. PD values for the same setups using the fetal shield were as follows: 1) 1.4-22 cGy, 2) 0.5-4 cGy, 3) 1.5-5 cGy and 4) under 1 cGy. Conclusions: The measured PD data sets can be used to estimate fetal dose for specific treatment setups and pregnancy stages. The use of external shield designed in this research reduced the fetal dose effectively to under the threshold (a 70-90% reduction), except for the final stages of pregnancy in Hodgkin’s patients. Iran. J. Radiat. Res., 2012 10(3‐4): 151‐156
Keywords: Fetal Dose, radiotherapy, pregnancy, fetal shield.
Full-Text [PDF 211 kb]   (2828 Downloads)    
Type of Study: Original Research | Subject: Radiation Biology
Send email to the article author

Add your comments about this article
Your username or Email:

CAPTCHA


XML     Print


Download citation:
BibTeX | RIS | EndNote | Medlars | ProCite | Reference Manager | RefWorks
Send citation to:

Atarod M, Shokrani P, Pourmoghadas A. Design of a generally applicable abdominal shield for reducing fetal dose during radiotherapy of common malignancies in pregnant patients. Int J Radiat Res 2012; 10 (3 and 4) :151-156
URL: http://ijrr.com/article-1-982-en.html


Rights and permissions
Creative Commons License This work is licensed under a Creative Commons Attribution-NonCommercial 4.0 International License.
Volume 10, Issue 3 And 4 (12-2012) Back to browse issues page
International Journal of Radiation Research
Persian site map - English site map - Created in 0.05 seconds with 50 queries by YEKTAWEB 4645