[Home ] [Archive]    
:: Main :: About :: Current Issue :: Archive :: Search :: Submit :: Contact ::
Main Menu
Home::
IJRR Information::
For Authors::
For Reviewers::
Subscription::
News & Events::
Web Mail::
::
Search in website

Advanced Search
..
Receive site information
Enter your Email in the following box to receive the site news and information.
..
ISSN
Hard Copy 2322-3243
Online 2345-4229
..
Online Submission
Now you can send your articles to IJRR office using the article submission system.
..

AWT IMAGE

AWT IMAGE

:: Search published articles ::
Showing 1 results for Parker

Dr. M.n. Anjum, W. Parker, I. Aldahlawi, R. Ruo, M. Afzal,
Volume 9, Issue 3 (12-2011)
Abstract

Background: We have validated the monitor unit calculations from a commercially available treatment planning system (TPS) for three intensity modulated radiotherapy (IMRT) planning techniques for tangential breast irradiation by using ionization chamber measurements. Materials and Methods: Treatment plans were generated for forty-two breast patients by a forward planned field in field technique, electronic tissue compensation (ETC), and an inverse planned sliding window technique. We also performed a reproducibility of delivery and dose linearity analysis for each technique. The treatments were delivered to a phantom using a Varian CL21EX linear accelerator. A 2571 0.6 cm3 Farmer type ionization chamber and Farmer 2570/1 electrometer from NE Technology was used to measure output of the linear accelerator and the dose at predefined point in the verification plan. Results: The agreement between the measured and calculated dose was -0.87% ± 0.54% for field in field technique, -0.74% ± 0.23% for electronic tissue compensators, and -1.26% ± 0.48% for the inverse planning technique and. In terms of reproducibility the mean deviation was -1.10% ± 0.44% for the field in field technique, -0.38% ± 0.42% for electronic tissue compensators, -1.04% ± 0.42% for inverse planning technique. Dose linearity experiments showed no significant variations for clinical situations but a breakdown was observed in relative dose for very low monitor units. Conclusion: We have found that the monitor unit calculations for all three planning techniques are correct to the order of 1%, and that the plans can be delivered in a reproducible and accurate manner. Iran. J. Radiat. Res., 2011 9(3): 145-150

Page 1 from 1     

International Journal of Radiation Research
Persian site map - English site map - Created in 0.15 seconds with 37 queries by YEKTAWEB 4714