:: Volume 18, Issue 4 (10-2020) ::
Int J Radiat Res 2020, 18(4): 875-884 Back to browse issues page
Estimating the cancer risk and mortalities induced by routine digital radiography examinations on patient of different ages in Mazandaran province
S.M. Hosseini , A. Banaei , Z. Hoseini Motlagh , R. Abedi-Firouzjah , F. Falahati , H. Zamani , Y. Moghimi
Department of Medical Physics Radiobiology and Radiation Protection, School of Medicine, Babol University of Medical Sciences, Babol, Iran , r.abedi@mubabol.ac.ir
Abstract:   (1995 Views)
Background: The aim of this study was to estimate the cancer risks and mortalities of different types induced by routine examinations of digital radiography for one year in Mazandaran province, Iran. Materials and methods: Radiation parameters and calculated entrance skin dose (ESD) values of 13 digital radiographic examinations were collected from 2340 patients at 18 high-patient-load radiography centers. Organ mean doses were estimated based on the collected parameters applying PCXMC software. The BEIR VII-Phase 2 model was used to calculate the induced cancer risks and mortalities of various cancer types at different ages. Results: The average ± standard deviation (SD) lifetime risks (incidence probability in 100,000 people) induced by radiations from radiography examinations for one year was 51.29±4.73 and 99.62±7.36 for new-born males and females, respectively. The lifetime cancer risk decreased with age and reached 3.77±0.62 and 4.88±0.07 for 80-year men and women, respectively. The average lifetime risks of mortality due to cancers induced by annual radiographies were obtained at 14.18±1.62 and 22.83±2.55 for new-born males and females, respectively. This risk reduced with age and was reached 1.97±0.27 and 2.45±0.38 for men and women at the age of 80 years, respectively. Conclusion: Our results showed that there are low but significant risks of cancer incidence for patients undergoing digital radiography, which included a large percentage of the population in Mazandaran province, especially for children and newborns. Therefore, further efforts like appropriate patient setup and beam geometry should be carried out to decrease patient doses.
Keywords: Digital radiography, cancer risk, cancer mortality, Mazandaran provience
Full-Text [PDF 1688 kb]   (813 Downloads)    
Type of Study: Original Research | Subject: Medical Physics



XML     Print



Rights and permissions
Creative Commons License This work is licensed under a Creative Commons Attribution-NonCommercial 4.0 International License.
Volume 18, Issue 4 (10-2020) Back to browse issues page