Int J Radiat Res 2011, 8(4): 231-236 Back to browse issues page
Dose estimation with the calibration of dose-response curve of micronucleus in human peripheral lymphocytes induced by 50MeV proton beams
Y.J. Go , J.H. Shin , K.S. Jeong , S.J. Park , S.H. Kim , S.Y. Ryu , C.H. Kim , E.J. Kim , Ch.M. Kang , TH. Kim
, thkim56@knu.ac.kr
Abstract:   (13047 Views)
Background: The purpose of this paper is to establish an easy and reliable biodosimeter protocol to evaluate the biological effects of proton beams. Materials and Methods: Human peripheral blood lymphocytes were irradiated using proton beams (LET: 34.6 keV μm−1), and the chromosome aberrations induced were analyzed using cytokinesis-blocked (CB) micronucleus (MN) assay. To determine the efficiency of MN assay in estimating the doses received by 50MeV proton beams and to monitor predicted dose of victims in accidental exposure, here we have evaluated the performance of MN analysis in a simulated situation after exposure with proton beams. Peripheral lymphocytes were irradiated by 50MeV proton beams up to 6Gy and analyzed by Giemsa staining of CB MN assay. Results: The detected MN was found to be a significant dose-effect curve in the manner of dose-dependent increase after exposure with proton beams in vitro. When plotting on a linear scale against radiation dose, the line of best fit was Y=0.004+(1.882x10-2±9.701x10-5) D+(1.43x10-3±1.571x10-5)D2. Our results show a trend towards increase of the number of MN with increasing dose. It was linear-quadratic and has a significant relationship between the frequencies of MN and dose (R2= 0.9996). The number of MN in lymphocyte that was observed in control group is 5.202±0.04/cell. Conclusion: Hence, this simple protocol will be particularly useful for helping physicians to decide medical therapy for the initial treatment of victims with rapid and precise dose estimation after accidental radiation exposure. Also it has potential for use as a valuable biomarker to evaluate the biological effectiveness for cancer therapy with proton beams. Iran. J. Radiat. Res., 2011 8(4): 231-236
Keywords: Human peripheral lymphocyte, biodosimetry, proton beams, dose estimation, triage.
Full-Text [PDF 353 kb]   (2889 Downloads)    
Type of Study: Original Research | Subject: Radiation Biology
Send email to the article author

Add your comments about this article
Your username or Email:

CAPTCHA


XML     Print


Download citation:
BibTeX | RIS | EndNote | Medlars | ProCite | Reference Manager | RefWorks
Send citation to:

Go Y, Shin J, Jeong K, Park S, Kim S, Ryu S, et al . Dose estimation with the calibration of dose-response curve of micronucleus in human peripheral lymphocytes induced by 50MeV proton beams. Int J Radiat Res 2011; 8 (4) :231-236
URL: http://ijrr.com/article-1-685-en.html


Rights and permissions
Creative Commons License This work is licensed under a Creative Commons Attribution-NonCommercial 4.0 International License.
Volume 8, Issue 4 (3-2011) Back to browse issues page
International Journal of Radiation Research
Persian site map - English site map - Created in 0.05 seconds with 50 queries by YEKTAWEB 4645