[Home ] [Archive]    
:: Main :: About :: Current Issue :: Archive :: Search :: Submit :: Contact ::
Main Menu
Home::
IJRR Information::
For Authors::
For Reviewers::
Subscription::
News & Events::
Web Mail::
::
Search in website

Advanced Search
..
Receive site information
Enter your Email in the following box to receive the site news and information.
..
ISSN
Hard Copy 2322-3243
Online 2345-4229
..
Online Submission
Now you can send your articles to IJRR office using the article submission system.
..

AWT IMAGE

AWT IMAGE

:: Volume 9, Issue 1 (6-2011) ::
Int J Radiat Res 2011, 9(1): 29-36 Back to browse issues page
Evaluation of the electron energy fluence and angular distributions from a clinical accelerator. A BEAMnrc Monte Carlo study
N. Jabbari , H. Nedaie , A. Zeinali
, njabbarimp@gmail.com
Abstract:   (12665 Views)
Background: Understanding of the incident electron energy and angular distributions from clinical electron accelerators (linacs) is important for dosimetry and treatment planning. The most important goals of this study were to evaluate the energy fluence and angular distributions of electron beams from a Neptun 10PC linac using the Monte Carlo (MC) code. Materials and Methods: The linac electron beams (6, 8, and 10 MeV) were modeled, using the BEAMnrc MC system based on the Electron- Gamma-Shower (EGSnrc) code. Central axis depthdose curves and dose profiles of the electron beams were measured experimentally, and calculated with the MC for three field sizes. In order to benchmarking the simulated models, the calculated and measured dose distributions were compared with Kolmogorov– Smirnov (KS) statistical test. Results: The KS test indicated that the calculated percent depth dose (PDD) and dose profile values for the three electron beam energies well agree with measured data (within 2% everywhere). The results also showed good agreement (discrepancies smaller than 1%) between the simulated electron energy parameters and those calculated from energy-range relationships using equations for the reference field size. Conclusion: The results showed that there was no significant difference between energy fluence curves of each electron beam energy at different field sizes. In addition, the results of the calculated angular distributions showed that the direction of the electron emerged from the treatment head and trimmer applicators were in forward direction. Iran. J. Radiat. Res., 2011 9(1): 29-36
Keywords: Linac, electron beam, energy fluence, angular distribution, Monte Carlo.
Full-Text [PDF 258 kb]   (4248 Downloads)    
Type of Study: Original Research | Subject: Radiation Biology
Send email to the article author

Add your comments about this article
Your username or Email:

CAPTCHA


XML     Print


Download citation:
BibTeX | RIS | EndNote | Medlars | ProCite | Reference Manager | RefWorks
Send citation to:

Jabbari N, Nedaie H, Zeinali A. Evaluation of the electron energy fluence and angular distributions from a clinical accelerator. A BEAMnrc Monte Carlo study. Int J Radiat Res 2011; 9 (1) :29-36
URL: http://ijrr.com/article-1-729-en.html


Rights and permissions
Creative Commons License This work is licensed under a Creative Commons Attribution-NonCommercial 4.0 International License.
Volume 9, Issue 1 (6-2011) Back to browse issues page
International Journal of Radiation Research
Persian site map - English site map - Created in 0.07 seconds with 50 queries by YEKTAWEB 4645