:: Volume 2, Issue 4 (3-2005) ::
Int J Radiat Res 2005, 2(4): 185-190 Back to browse issues page
Estimation of the effective dose to the radiologists during fluoroscopy or angiography of abdominal viscera
M. Hajizadeh Saffar , S. Nekoee , M.H. Bahrayni-Toosi , A. Sedghi
, hajizadeh@mums.ac.ir
Abstract:   (18626 Views)

ABSTRACT

Background:

as fluoroscopy or different angiographies are usually evaluated using TL dosimeter. This

method is a time-consuming procedure therefore, radiologists are usually worried and unaware

of their exact radiation dose received during each fluoroscopy or angiography. In this study, a

new trend for quick estimation of effective dose based on measuring air-absorbed dose of the

scattered radiations at body surface of the radiologists has been introduced.

The radiation effective dose received by the radiologists during procedures such

Materials and Methods:

fluoroscopy unit (Shimatsu, model SF5010MD), and a water phantom (spherical plastic bag 27

cm in diameter filled with water up to 22.5 cm height). Radiation field was 20 × 20 cm on the

bed and X-ray tube had 1.5 and 2 mm of Aluminum as an internal and external filtration

respectively. A calibrated survey meter model RDS-110 was used to measure the scattered

radiation horizontally and vertically around the phantom at different angles and distances, in

front and behind of an apron.

Scattered radiations of abdominal viscera were simulated by a

Results:

mA, was 451 µGy/h. This value reduced to 4.45 µGy/h by passing through lead ribbons of

serigraph and to 1.2 µSv/h behind an apron. The scattered dose rate at different angles above the

bed was constant and varied by distance from the center of the radiation field. The effective

dose received by the radiologist is estimated to be about 174µGy/h, while wearing an apron and

staying 50 cm away from the patient during fluoroscopy or angiography of abdominal viscera.

The scattered dose rate at 1 m from the phantom, during fluoroscopy at 83 kVp and 1.7 

Conclusion:

different angiographies of abdominal viscera, by determining scatter radiation dose at their body

surface and applying factor 0.87 for shielding effect of the body. Equivalent organ dose can also

be calculated from dose rate in air after applying factor 0.87 for deep organs or 1.1 (the mass

energy absorption coefficient ratio of water/tissue to air) for organs near the surface.

Radiat. Res., 2005 2 (4): 185-190

The radiologist can estimate his/her effective dose following a fluoroscopy orIran. J.
Keywords: angiography, fluoroscopy, radiologist, Effective dose, phantom
Full-Text [PDF 191 kb]   (3452 Downloads)    
Type of Study: Original Research | Subject: Radiation Biology


XML     Print



Rights and permissions
Creative Commons License This work is licensed under a Creative Commons Attribution-NonCommercial 4.0 International License.
Volume 2, Issue 4 (3-2005) Back to browse issues page