<?xml version="1.0" encoding="utf-8"?>
<journal>
<title>International Journal of Radiation Research</title>
<title_fa>نشریه پرتو پژوه</title_fa>
<short_title>Int J Radiat Res</short_title>
<subject>Basic Sciences</subject>
<web_url>http://ijrr.com</web_url>
<journal_hbi_system_id>79</journal_hbi_system_id>
<journal_hbi_system_user>journal79</journal_hbi_system_user>
<journal_id_issn>2322-3243</journal_id_issn>
<journal_id_issn_online>2345-4229</journal_id_issn_online>
<journal_id_pii></journal_id_pii>
<journal_id_doi>10.61882/ijrr</journal_id_doi>
<journal_id_iranmedex></journal_id_iranmedex>
<journal_id_magiran></journal_id_magiran>
<journal_id_sid></journal_id_sid>
<journal_id_nlai></journal_id_nlai>
<journal_id_science></journal_id_science>
<language>en</language>
<pubdate>
	<type>jalali</type>
	<year>1391</year>
	<month>10</month>
	<day>1</day>
</pubdate>
<pubdate>
	<type>gregorian</type>
	<year>2013</year>
	<month>1</month>
	<day>1</day>
</pubdate>
<volume>11</volume>
<number>1</number>
<publish_type>online</publish_type>
<publish_edition>1</publish_edition>
<article_type>fulltext</article_type>
<articleset>
	<article>


	<language>en</language>
	<article_id_doi></article_id_doi>
	<title_fa></title_fa>
	<title>Evaluating the effect of energy on calibration of thermo-luminescent dosimeters 7-LiF:Mg,Cu,P (GR-207A)</title>
	<subject_fa>Radiation Biology</subject_fa>
	<subject>Radiation Biology</subject>
	<content_type_fa>تحقيق بديع</content_type_fa>
	<content_type>Original Research</content_type>
	<abstract_fa></abstract_fa>
	<abstract>&lt;p&gt;&lt;strong&gt;Background:&lt;/strong&gt; 7-LiF: Mg,Cu,P (GR-207A) is one kind of thermo-luminescent dosimeters (TLD) which can be used in diagnostic radiology and radiotherapy applications. Because of having suitable properties such as good sensitivity, small size and being tissue equivalent, thermo-luminescent dosimetry has been one of the most important techniques in medicine over many years. Choosing a correct energy for TLDs&amp;rsquo; calibration is one of the most important factors in the accuracy of the absorbed dose. &lt;strong&gt;Materials and Methods:&lt;/strong&gt; In order to evaluate the effect of calibration energy on the response of GR-207A TLDs, calibration of the TLDs were done with 120kVp, 200kVp, 6MV, 18MV and &lt;sup&gt;60&lt;/sup&gt;Co beams. Then the responses of TLDs were normalized to &lt;sup&gt;60&lt;/sup&gt;Co and energy dependence was calculated for each dose step.&lt;strong&gt; Results:&lt;/strong&gt; The results confirmed that this kind of TLD dose not have the same response in different energies and reference dose affects on the amount of energy dependence. &lt;strong&gt;Discussion:&lt;/strong&gt; Energy dependence of this type of TLDs is more significant at lower energies compared to megavoltage beams. Relative response to &lt;sup&gt;60&lt;/sup&gt;Co illustrates that GR-207A dose not have uniform response to different steps of energies and the amount of energy dependence is totally different in various dose levels.&lt;/p&gt;
</abstract>
	<keyword_fa></keyword_fa>
	<keyword>Dosimetry, thermo-luminescent dosimeters, TLD, energy dependence</keyword>
	<start_page>51</start_page>
	<end_page>54</end_page>
	<web_url>http://ijrr.com/browse.php?a_code=A-10-1-454&amp;slc_lang=en&amp;sid=1</web_url>


<author_list>
	<author>
	<first_name>N.</first_name>
	<middle_name></middle_name>
	<last_name>Banaee</last_name>
	<suffix></suffix>
	<first_name_fa></first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa></last_name_fa>
	<suffix_fa></suffix_fa>
	<email>Nooshin_banaee@yahoo.com</email>
	<code>790031947532846007476</code>
	<orcid>790031947532846007476</orcid>
	<coreauthor>Yes
</coreauthor>
	<affiliation>Department of Engineering, Science and Research Branch, Islamic Azad University, Tehran, Iran</affiliation>
	<affiliation_fa></affiliation_fa>
	 </author>


	<author>
	<first_name>H.A.</first_name>
	<middle_name></middle_name>
	<last_name>Nedaie</last_name>
	<suffix></suffix>
	<first_name_fa></first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa></last_name_fa>
	<suffix_fa></suffix_fa>
	<email></email>
	<code>790031947532846007477</code>
	<orcid>790031947532846007477</orcid>
	<coreauthor>No</coreauthor>
	<affiliation>2Radiotherapy Oncology Department, Cancer Research Centre, Tehran University of Medical Sciences, Tehran, Iran</affiliation>
	<affiliation_fa></affiliation_fa>
	 </author>


</author_list>


	</article>
</articleset>
</journal>
