<?xml version="1.0" encoding="utf-8"?>
<journal>
<title>International Journal of Radiation Research</title>
<title_fa>نشریه پرتو پژوه</title_fa>
<short_title>Int J Radiat Res</short_title>
<subject>Basic Sciences</subject>
<web_url>http://ijrr.com</web_url>
<journal_hbi_system_id>79</journal_hbi_system_id>
<journal_hbi_system_user>journal79</journal_hbi_system_user>
<journal_id_issn>2322-3243</journal_id_issn>
<journal_id_issn_online>2345-4229</journal_id_issn_online>
<journal_id_pii></journal_id_pii>
<journal_id_doi>10.61882/ijrr</journal_id_doi>
<journal_id_iranmedex></journal_id_iranmedex>
<journal_id_magiran></journal_id_magiran>
<journal_id_sid></journal_id_sid>
<journal_id_nlai></journal_id_nlai>
<journal_id_science></journal_id_science>
<language>en</language>
<pubdate>
	<type>jalali</type>
	<year>1397</year>
	<month>1</month>
	<day>1</day>
</pubdate>
<pubdate>
	<type>gregorian</type>
	<year>2018</year>
	<month>4</month>
	<day>1</day>
</pubdate>
<volume>16</volume>
<number>2</number>
<publish_type>online</publish_type>
<publish_edition>1</publish_edition>
<article_type>fulltext</article_type>
<articleset>
	<article>


	<language>en</language>
	<article_id_doi></article_id_doi>
	<title_fa></title_fa>
	<title>Prospective-triggered high-pitch spiral versus sequential dual-source CT coronary angiography: comparison of image quality and radiation dose
</title>
	<subject_fa>Radiation Biology</subject_fa>
	<subject>Radiation Biology</subject>
	<content_type_fa>تحقيق بديع</content_type_fa>
	<content_type>Original Research</content_type>
	<abstract_fa></abstract_fa>
	<abstract>&lt;div style=&quot;text-align: justify;&quot;&gt;Background: Prospectively electrocardiography (ECG)-triggered high-pitch spiral coronary computed tomography angiography (CCTA) is a unique scan mode for dual-source CT (DSCT). Our reports aim to compare image quality and radiation dose of CCTA using high-pitch spiral or sequential acquisition mode in patients with low and stable heart rates. Materials and Methods: Patients with low and stable heart rates (HR) (HR &amp;le; 70 beats per minute [bpm]; heart rate variability [HRV] &lt; 10 bpm) were randomly assigned to high-pitch spiral mode (group A; n = 80) or sequential acquisition mode (group B; n = 80). Image quality scores, image noise, effective radiation dose and influencing factors on image quality were assessed. &amp;nbsp;Results: Mean image quality scores were 1.51 &amp;plusmn; 0.32 and 1.70 &amp;plusmn; 0.38 for groups A and B (P &lt; 0.05), respectively. Image noises of the two groups were 19.05&amp;plusmn;4.70 Hu and 27.21&amp;plusmn;8.88 Hu (P &lt; 0.05). Contrast media cost in group A was lower than group B (P &lt; 0.05). No statistical difference was found in the rate of diagnostic patients between the two groups (P = 0.416). The estimated radiation dose of group A was 26.0% reduced compared with group B (0.74 &amp;plusmn; 0.34 mSv vs. 1.00 &amp;plusmn; 0.48 mSv, P &lt; 0.05). Conclusion: In patients with regular and low heart rates, the prospectively high-pitch spiral acquisition mode can reduce radiation dose and contrast media cost while maintaining image quality compared with the prospectively sequential mode.&lt;br&gt;
&amp;nbsp;&lt;/div&gt;
</abstract>
	<keyword_fa></keyword_fa>
	<keyword>Tomography, X-ray computed, coronary angiography, image quality, radiation dose. 
</keyword>
	<start_page>225</start_page>
	<end_page>233</end_page>
	<web_url>http://ijrr.com/browse.php?a_code=A-10-1-720&amp;slc_lang=en&amp;sid=1</web_url>


<author_list>
	<author>
	<first_name>Y. </first_name>
	<middle_name></middle_name>
	<last_name>Zhuang</last_name>
	<suffix></suffix>
	<first_name_fa></first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa></last_name_fa>
	<suffix_fa></suffix_fa>
	<email></email>
	<code>7900319475328460011447</code>
	<orcid>7900319475328460011447</orcid>
	<coreauthor>No</coreauthor>
	<affiliation>Shandong Medical Imaging Research Institute, Shandong University, No. 324, JingWu Road, Jinan 250021, Shandong, China</affiliation>
	<affiliation_fa></affiliation_fa>
	 </author>


	<author>
	<first_name>W. </first_name>
	<middle_name></middle_name>
	<last_name>Huang</last_name>
	<suffix></suffix>
	<first_name_fa></first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa></last_name_fa>
	<suffix_fa></suffix_fa>
	<email></email>
	<code>7900319475328460011448</code>
	<orcid>7900319475328460011448</orcid>
	<coreauthor>No</coreauthor>
	<affiliation>Department of Medical Imaging, Huai’an First People’s Hospital, Affiliated to Nanjing Medical University No.6, Western Beijing Road, Huanyin District, Huai’an 223300, Jiangsu, China</affiliation>
	<affiliation_fa></affiliation_fa>
	 </author>


	<author>
	<first_name>Y. </first_name>
	<middle_name></middle_name>
	<last_name>Shi</last_name>
	<suffix></suffix>
	<first_name_fa></first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa></last_name_fa>
	<suffix_fa></suffix_fa>
	<email></email>
	<code>7900319475328460011449</code>
	<orcid>7900319475328460011449</orcid>
	<coreauthor>No</coreauthor>
	<affiliation>Digestive Department, Huai’an First People’s Hospital, Affiliated to Nanjing Medical University No.6, Western Beijing Road, Huanyin District, Huai’an 223300, Jiangsu, China</affiliation>
	<affiliation_fa></affiliation_fa>
	 </author>


	<author>
	<first_name>G. </first_name>
	<middle_name></middle_name>
	<last_name>Bo</last_name>
	<suffix></suffix>
	<first_name_fa></first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa></last_name_fa>
	<suffix_fa></suffix_fa>
	<email></email>
	<code>7900319475328460011450</code>
	<orcid>7900319475328460011450</orcid>
	<coreauthor>No</coreauthor>
	<affiliation>Department of Medical Imaging, Huai’an First People’s Hospital, Affiliated to Nanjing Medical University No.6, Western Beijing Road, Huanyin District, Huai’an 223300, Jiangsu, China</affiliation>
	<affiliation_fa></affiliation_fa>
	 </author>


	<author>
	<first_name>D. </first_name>
	<middle_name></middle_name>
	<last_name>Lu</last_name>
	<suffix></suffix>
	<first_name_fa></first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa></last_name_fa>
	<suffix_fa></suffix_fa>
	<email></email>
	<code>7900319475328460011451</code>
	<orcid>7900319475328460011451</orcid>
	<coreauthor>No</coreauthor>
	<affiliation>Department of Medical Imaging, Huai’an First People’s Hospital, Affiliated to Nanjing Medical University No.6, Western Beijing Road, Huanyin District, Huai’an 223300, Jiangsu, China</affiliation>
	<affiliation_fa></affiliation_fa>
	 </author>


	<author>
	<first_name>J. </first_name>
	<middle_name></middle_name>
	<last_name>Zhang</last_name>
	<suffix></suffix>
	<first_name_fa></first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa></last_name_fa>
	<suffix_fa></suffix_fa>
	<email></email>
	<code>7900319475328460011452</code>
	<orcid>7900319475328460011452</orcid>
	<coreauthor>No</coreauthor>
	<affiliation>Department of Medical Imaging, Huai’an First People’s Hospital, Affiliated to Nanjing Medical University No.6, Western Beijing Road, Huanyin District, Huai’an 223300, Jiangsu, China</affiliation>
	<affiliation_fa></affiliation_fa>
	 </author>


	<author>
	<first_name>D. </first_name>
	<middle_name></middle_name>
	<last_name>Kong</last_name>
	<suffix></suffix>
	<first_name_fa></first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa></last_name_fa>
	<suffix_fa></suffix_fa>
	<email></email>
	<code>7900319475328460011453</code>
	<orcid>7900319475328460011453</orcid>
	<coreauthor>No</coreauthor>
	<affiliation>Department of Medical Imaging, Huai’an First People’s Hospital, Affiliated to Nanjing Medical University No.6, Western Beijing Road, Huanyin District, Huai’an 223300, Jiangsu, China</affiliation>
	<affiliation_fa></affiliation_fa>
	 </author>


	<author>
	<first_name>Y. </first_name>
	<middle_name></middle_name>
	<last_name>Shi</last_name>
	<suffix></suffix>
	<first_name_fa></first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa></last_name_fa>
	<suffix_fa></suffix_fa>
	<email></email>
	<code>7900319475328460011454</code>
	<orcid>7900319475328460011454</orcid>
	<coreauthor>No</coreauthor>
	<affiliation>Department of Medical Imaging, Huai’an First People’s Hospital, Affiliated to Nanjing Medical University No.6, Western Beijing Road, Huanyin District, Huai’an 223300, Jiangsu, China</affiliation>
	<affiliation_fa></affiliation_fa>
	 </author>


	<author>
	<first_name>B.</first_name>
	<middle_name></middle_name>
	<last_name>Wang</last_name>
	<suffix></suffix>
	<first_name_fa></first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa></last_name_fa>
	<suffix_fa></suffix_fa>
	<email>binwang001@aliyun.com </email>
	<code>7900319475328460011455</code>
	<orcid>7900319475328460011455</orcid>
	<coreauthor>Yes
</coreauthor>
	<affiliation>Binzhou Medical University, No. 346, Guanhai Road, Laishan District, Yantai 264003, Shandong, China</affiliation>
	<affiliation_fa></affiliation_fa>
	 </author>


</author_list>


	</article>
</articleset>
</journal>
