[Home ] [Archive]    
:: Main :: About :: Current Issue :: Archive :: Search :: Submit :: Contact ::
Main Menu
Home::
IJRR Information::
For Authors::
For Reviewers::
Subscription::
News & Events::
Web Mail::
::
Search in website

Advanced Search
..
Receive site information
Enter your Email in the following box to receive the site news and information.
..
ISSN
Hard Copy 2322-3243
Online 2345-4229
..
Online Submission
Now you can send your articles to IJRR office using the article submission system.
..

AWT IMAGE

AWT IMAGE

:: Volume 12, Issue 4 (10-2014) ::
Int J Radiat Res 2014, 12(4): 325-330 Back to browse issues page
HVL evaluation of orthovoltage X-ray machine using EGSnrc code of simulation
A. Shabestani Monfared , T. Allahverdi Pourfallah , H. Babapour , A.R. Shirazi
Biochemistry and Biophysics Department, Faculty of Medicine, Mazandaran University of Medical Sciences, Sari, Iran , tpourfallah@mazums.ac.ir
Abstract:   (7886 Views)

Background: Making use of the orthovoltage machines in Radiotherapy, is one of the routine methods for the treatment of the superficial lesions. In this study, an important determinant of X-ray quality, the HVL (Half Value Layer), has been evaluated. Materials and Methods: The HVLs of a orthovoltage X-ray machine in 120 and 180 kVp are measured, using an empirical method, in which the HVLs are derived from the absorption curves. The measured HVLs are compared with calculated (Monte Carlo simulation) HVLs. Using the BEAMDP code of simulation, the output spectra are obtained and employed for the measurement of the HVLs. Results: Comparing the calculated and measured HVL values, the results show that the highest and lowest differences between the two are 4.96% and 2.27%, respectively, which are, in fairly good agreement with those obtained in the former studies. Conclusion: This study shows that the EGSnrc simulation code is capable of being used for the extraction of the quality indices for the superficial X-ray radiotherapy machines. It seems that, the mentioned code, with the mentioned experimental method, can be employed as a routine clinical test tool for every superficial radiotherapy department.

Keywords: HVL, EGSnrc, MC simulation, orthovoltage machine
Full-Text [PDF 603 kb]   (3929 Downloads)    
Type of Study: Original Research | Subject: Radiation Biology
Send email to the article author

Add your comments about this article
Your username or Email:

CAPTCHA


XML     Print


Download citation:
BibTeX | RIS | EndNote | Medlars | ProCite | Reference Manager | RefWorks
Send citation to:

Shabestani Monfared A, Allahverdi Pourfallah T, Babapour H, Shirazi A. HVL evaluation of orthovoltage X-ray machine using EGSnrc code of simulation. Int J Radiat Res 2014; 12 (4) :325-330
URL: http://ijrr.com/article-1-1350-en.html


Rights and permissions
Creative Commons License This work is licensed under a Creative Commons Attribution-NonCommercial 4.0 International License.
Volume 12, Issue 4 (10-2014) Back to browse issues page
International Journal of Radiation Research
Persian site map - English site map - Created in 0.05 seconds with 50 queries by YEKTAWEB 4660