[Home ] [Archive]    
:: Main :: About :: Current Issue :: Archive :: Search :: Submit :: Contact ::
Main Menu
Home::
IJRR Information::
For Authors::
For Reviewers::
Subscription::
News & Events::
Web Mail::
::
Search in website

Advanced Search
..
Receive site information
Enter your Email in the following box to receive the site news and information.
..
ISSN
Hard Copy 2322-3243
Online 2345-4229
..
Online Submission
Now you can send your articles to IJRR office using the article submission system.
..

AWT IMAGE

AWT IMAGE

:: Volume 14, Issue 1 (1-2016) ::
Int J Radiat Res 2016, 14(1): 73-76 Back to browse issues page
Response of TLD and RPL personal dosimeters in a national inter-comparison test program
N. Navab Moghadam , S.M. Hosseini Pooya , H. Afarideh , M.R. Kardan
Nuclear Science and Technology Research Institute , mhosseini@aeoi.org.ir
Abstract:   (6944 Views)

Background: Different kinds and models of personal dosimeters are used in individual monitoring by workers.  Performance testing as part of approval procedures is carried out to demonstrate that the essential performance specifications are routinely maintained. There are four service providers in Iran which use different luminescence techniques (i. e. TLD and RPL) with various kinds of dosimeter materials/reader instruments in personal dosimetry services. Materials and Methods: A national performance approval tests program was performed for the dosimeters of the service providers in energy range of soft, 660 keV and 1.25 MeV, at the doses values around the recoding, investigation and annual dose limits, and different angle of incidents (e. g. 0, 20, 40 and 60 degree). Results: The results of this testing satisfies the overall accuracy criteria with 95% confidence levels specified by the ICRP,  except that of RPL technique in low energy  which overestimates the dose out of the acceptable accuracy band defined as the ICRP trumpet curves. Conclusion: The inter-comparison has proved that the personal dose equivalent quantity, Hp(10), defined by the ICRU and recommended by the IAEA are becoming widely accepted and implemented in most participated laboratories.

Keywords: TLD, RPL, dosimetry, inter-comparison, individual, performance, tests
Full-Text [PDF 625 kb]   (3277 Downloads)    
Type of Study: Short Report | Subject: Radiation Biology
Send email to the article author

Add your comments about this article
Your username or Email:

CAPTCHA



XML     Print


Download citation:
BibTeX | RIS | EndNote | Medlars | ProCite | Reference Manager | RefWorks
Send citation to:

Navab Moghadam N, Hosseini Pooya S, Afarideh H, Kardan M. Response of TLD and RPL personal dosimeters in a national inter-comparison test program . Int J Radiat Res 2016; 14 (1) :73-76
URL: http://ijrr.com/article-1-1680-en.html


Rights and permissions
Creative Commons License This work is licensed under a Creative Commons Attribution-NonCommercial 4.0 International License.
Volume 14, Issue 1 (1-2016) Back to browse issues page
International Journal of Radiation Research
Persian site map - English site map - Created in 0.1 seconds with 50 queries by YEKTAWEB 4700