[Home ] [Archive]    
:: Main :: About :: Current Issue :: Archive :: Search :: Submit :: Contact ::
Main Menu
Home::
IJRR Information::
For Authors::
For Reviewers::
Subscription::
News & Events::
Web Mail::
::
Search in website

Advanced Search
..
Receive site information
Enter your Email in the following box to receive the site news and information.
..
ISSN
Hard Copy 2322-3243
Online 2345-4229
..
Online Submission
Now you can send your articles to IJRR office using the article submission system.
..

AWT IMAGE

AWT IMAGE

:: Volume 15, Issue 2 (4-2017) ::
Int J Radiat Res 2017, 15(2): 177-183 Back to browse issues page
Radiation treatment planning for prostate cancer: A new dosimetric comparison of five and seven fields IMRT plans
S.R.M. Mahdavi , E. Jazayeri Gharehbagh , A.R. Nikoofar , B. Mofid , M. Vasheghani , D. Saedi
Department of Radiation Oncology, Iran University of Medical Sciences, Tehran, Iran , arnikoofar@gmail.com
Abstract:   (5504 Views)

Background: To compare the dosimetric coverage of the planning target volume (PTV) and the dose delivered to the main Organs at Risk (OARs) in 5 and 7-field techniques of Intensity Modulated Radiation Therapy (IMRT) in patients with local prostate cancer. Materials and Methods: Twelve patients with local prostate cancer underwent 5 and 7-field IMRT planning. The delivery of IMRT was carried out using the sliding technique. The dose coverage for PTV was designated to ≥98% of the PTV covered by 95% of the prescribed dose. Dose conformity was evaluated by comparing the volume of nontarget tissue receiving maximum, and average of the prescribed dose and the dose of 33%, 50%, and 66% of the volumes on both planning sets. For target, this evaluation was made with comparing the Conformity Index (CI) and Inhomogeneity Index (HI). In addition, we compared the monitor units used for dose delivery in both planning techniques. Results: All the 5 and 7-field IMRT plans differed slightly in the measured parameters, and none of them have statistically significant differences with each other except for the monitor units where significant differences were observed in favor of the 5-field IMRT plans (p=0.000). In all of the 5-field IMRT plans the mean dose delivered to OARs were very similar or less than that of the 7-field plans. Conclusion: In comparison to the 7-field technique, the 5-field IMRT technique has resulted in improved IMRT dose conformity, homogeneity, and lesser MUs used for radiation therapy. However, this difference was not significant.

Keywords: IMRT, dose conformity, MUs, prostate cancer
Full-Text [PDF 642 kb]   (3767 Downloads)    
Type of Study: Short Report | Subject: Radiation Biology
Send email to the article author

Add your comments about this article
Your username or Email:

CAPTCHA



XML     Print


Download citation:
BibTeX | RIS | EndNote | Medlars | ProCite | Reference Manager | RefWorks
Send citation to:

Mahdavi S, Jazayeri Gharehbagh E, Nikoofar A, Mofid B, Vasheghani M, Saedi D. Radiation treatment planning for prostate cancer: A new dosimetric comparison of five and seven fields IMRT plans . Int J Radiat Res 2017; 15 (2) :177-183
URL: http://ijrr.com/article-1-1962-en.html


Rights and permissions
Creative Commons License This work is licensed under a Creative Commons Attribution-NonCommercial 4.0 International License.
Volume 15, Issue 2 (4-2017) Back to browse issues page
International Journal of Radiation Research
Persian site map - English site map - Created in 0.05 seconds with 50 queries by YEKTAWEB 4660