Volume 4, Issue 1 (Summer 2006)                   Int J Radiat Res 2006, 4(1): 21-28 | Back to browse issues page

XML Print


Download citation:
BibTeX | RIS | EndNote | Medlars | ProCite | Reference Manager | RefWorks
Send citation to:

Bahreyni Toosi M, Nazery M, Zare H. Application of Dose-Area Product compared with three other dosimetric quantities used to estimate patient effective dose in diagnostic radiology. Int J Radiat Res 2006; 4 (1) :21-28
URL: http://ijrr.com/article-1-208-en.html
, m-t-bahreyni@mums.ac.ir
Abstract:   (18013 Views)
Background: Application of Dose-area product (DAP) quantity has been increased in the clinical practice. DAP is relatively easy to measure. DAP has been shown to correlate well with the total energy imparted to the patient, which is related to the effective dose. Material and Methods: In this study, measurements of DAP were carried out in a sample of 421 adult patients who underwent conventional radiological examinations. Then, by using DAP some useful dosimetric quantities such as exposure area product (EAP), air kerma and entrance surface dose (ESD) were estimated. Furthermore, ESD was calculated by a Multi-O-Meter dosemeter. Effective doses were computed by measurement of DAP and corresponding conversion factors. Finally, the effective dose was determined using: i) ESD and data published by NRPB. ii) energy imparted derived from DAP, and iii) ODS-60 package. Results: The effective dose values derived from the four methods are in good agreement. The mean effective dose estimated from DAP measurement were 0.13, 0.42, 0.05, 0.59, 0.54 and 0.03 mSv/projection for chest, abdomen, cervical spine, lumbar spine, pelvis and skull examinations, respectively. Conclusion: Indirect effective dose determination using the NRPB dosimetric data and the measured value of DAP or ESD allows for reliable estimates of effective dose. The ODS-60 software was used in this study because it has the flexibility to manipulate the technical parameters of an examination and patient's parameters.
Full-Text [PDF 352 kb]   (16155 Downloads)    
Type of Study: Original Research | Subject: Radiation Biology

Add your comments about this article : Your username or Email:
CAPTCHA

Send email to the article author


Rights and permissions
Creative Commons License This work is licensed under a Creative Commons Attribution-NonCommercial 4.0 International License.

International Journal of Radiation Research
Persian site map - English site map - Created in 0.09 seconds with 50 queries by YEKTAWEB 4722