[Home ] [Archive]    
:: Main :: About :: Current Issue :: Archive :: Search :: Submit :: Contact ::
Main Menu
Home::
IJRR Information::
For Authors::
For Reviewers::
Subscription::
News & Events::
Web Mail::
::
Search in website

Advanced Search
..
Receive site information
Enter your Email in the following box to receive the site news and information.
..
ISSN
Hard Copy 2322-3243
Online 2345-4229
..
Online Submission
Now you can send your articles to IJRR office using the article submission system.
..

AWT IMAGE

AWT IMAGE

:: Volume 4, Issue 1 (Summer 2006) ::
Int J Radiat Res 2006, 4(1): 21-28 Back to browse issues page
Application of Dose-Area Product compared with three other dosimetric quantities used to estimate patient effective dose in diagnostic radiology
M.T. Bahreyni Toosi , M. Nazery , H. Zare
, m-t-bahreyni@mums.ac.ir
Abstract:   (17061 Views)
Background: Application of Dose-area product (DAP) quantity has been increased in the clinical practice. DAP is relatively easy to measure. DAP has been shown to correlate well with the total energy imparted to the patient, which is related to the effective dose. Material and Methods: In this study, measurements of DAP were carried out in a sample of 421 adult patients who underwent conventional radiological examinations. Then, by using DAP some useful dosimetric quantities such as exposure area product (EAP), air kerma and entrance surface dose (ESD) were estimated. Furthermore, ESD was calculated by a Multi-O-Meter dosemeter. Effective doses were computed by measurement of DAP and corresponding conversion factors. Finally, the effective dose was determined using: i) ESD and data published by NRPB. ii) energy imparted derived from DAP, and iii) ODS-60 package. Results: The effective dose values derived from the four methods are in good agreement. The mean effective dose estimated from DAP measurement were 0.13, 0.42, 0.05, 0.59, 0.54 and 0.03 mSv/projection for chest, abdomen, cervical spine, lumbar spine, pelvis and skull examinations, respectively. Conclusion: Indirect effective dose determination using the NRPB dosimetric data and the measured value of DAP or ESD allows for reliable estimates of effective dose. The ODS-60 software was used in this study because it has the flexibility to manipulate the technical parameters of an examination and patient's parameters.
Keywords: Effective dose, Diagnostic radiology, DAP
Full-Text [PDF 352 kb]   (14421 Downloads)    
Type of Study: Original Research | Subject: Radiation Biology
Send email to the article author

Add your comments about this article
Your username or Email:

CAPTCHA


XML     Print


Download citation:
BibTeX | RIS | EndNote | Medlars | ProCite | Reference Manager | RefWorks
Send citation to:

Bahreyni Toosi M, Nazery M, Zare H. Application of Dose-Area Product compared with three other dosimetric quantities used to estimate patient effective dose in diagnostic radiology. Int J Radiat Res 2006; 4 (1) :21-28
URL: http://ijrr.com/article-1-208-en.html


Rights and permissions
Creative Commons License This work is licensed under a Creative Commons Attribution-NonCommercial 4.0 International License.
Volume 4, Issue 1 (Summer 2006) Back to browse issues page
International Journal of Radiation Research
Persian site map - English site map - Created in 0.05 seconds with 50 queries by YEKTAWEB 4645