[Home ] [Archive]    
:: Main :: About :: Current Issue :: Archive :: Search :: Submit :: Contact ::
Main Menu
Home::
IJRR Information::
For Authors::
For Reviewers::
Subscription::
News & Events::
Web Mail::
::
Search in website

Advanced Search
..
Receive site information
Enter your Email in the following box to receive the site news and information.
..
ISSN
Hard Copy 2322-3243
Online 2345-4229
..
Online Submission
Now you can send your articles to IJRR office using the article submission system.
..

AWT IMAGE

AWT IMAGE

:: Volume 16, Issue 1 (1-2018) ::
Int J Radiat Res 2018, 16(1): 123-127 Back to browse issues page
Determination of hemolysis, osmotic fragility and fluorescence anisotropy on irradiated red blood cells as a function of kV of medical diagnostic X-rays
M. Tungjai , N. Phathakanon , P. Ketnuam , J. Tinlapat , S. Kothan
Department of Radiologic Technology, Faculty of Associated Medical Sciences, Chiang Mai University, 110 Intawaroroj Rd., Sripoom, Chiang Mai, 50200, Thailand , mtungjai@gmail.com
Abstract:   (4854 Views)
Background: People occasionally undergo medical diagnostic X-ray examinations and expose their red blood cells to radiation. Radiation that is generated from medical diagnostic X-ray machines is widely used in medical diagnoses. One of the important parameters is kilo-voltage (kV) that is applied across the X-ray tube in medical diagnostic X-ray machines. Kilo-voltage influences the radiation dosage. The aim of this study is to determine the hemolysis, osmotic fragility, and fluorescence anisotropy value on irradiated red blood cells as a function of kV during medical diagnostic X-ray examinations.  Materials and Methods: The kV, kilo-voltage that is applied across an  X-ray tube, of a medical diagnostic X-ray machine was operated at 50, 70 and 100 kV. We determined the hemolysis, osmotic fragility, and fluorescence anisotropy value in red blood cells at 0.5 and 4 hours post-irradiation. In order to determine hemolysis and osmotic fragility, the release of hemoglobin was measured by spectrophotometry technique. 1,6-diphenyl-1,3,5-hexatriene (DPH) was used as a molecular probe for determining fluorescence anisotropy value by fluorescence anisotropy technique. Non-irradiated red blood cells served as the control. Results: For the 50, 70, and 100 kV of medical diagnostic X-rays, the hemolysis, osmotic fragility, and fluorescence anisotropy values of irradiated red blood cells at 0.5 and 4 hours post-irradiation did not significantly change when compared to the control.  Conclusion: Our results suggested that 50, 70, and 100 kV of medical diagnostic X-ray did not influence hemolysis, osmotic fragility, and fluorescence anisotropy values of irradiated red blood cells.
 
Keywords: Medical diagnostic X-ray, red blood cell, hemolysis, osmotic fragility, fluorescence anisotropy.
Full-Text [PDF 1190 kb]   (5821 Downloads)    
Type of Study: Original Research | Subject: Radiation Biology
Send email to the article author

Add your comments about this article
Your username or Email:

CAPTCHA



XML     Print


Download citation:
BibTeX | RIS | EndNote | Medlars | ProCite | Reference Manager | RefWorks
Send citation to:

Tungjai M, Phathakanon N, Ketnuam P, Tinlapat J, Kothan S. Determination of hemolysis, osmotic fragility and fluorescence anisotropy on irradiated red blood cells as a function of kV of medical diagnostic X-rays. Int J Radiat Res 2018; 16 (1) :123-127
URL: http://ijrr.com/article-1-2149-en.html


Rights and permissions
Creative Commons License This work is licensed under a Creative Commons Attribution-NonCommercial 4.0 International License.
Volume 16, Issue 1 (1-2018) Back to browse issues page
International Journal of Radiation Research
Persian site map - English site map - Created in 0.05 seconds with 50 queries by YEKTAWEB 4645