[Home ] [Archive]    
:: Main :: About :: Current Issue :: Archive :: Search :: Submit :: Contact ::
Main Menu
Home::
IJRR Information::
For Authors::
For Reviewers::
Subscription::
News & Events::
Web Mail::
::
Search in website

Advanced Search
..
Receive site information
Enter your Email in the following box to receive the site news and information.
..
ISSN
Hard Copy 2322-3243
Online 2345-4229
..
Online Submission
Now you can send your articles to IJRR office using the article submission system.
..

AWT IMAGE

AWT IMAGE

:: Volume 17, Issue 3 (6-2019) ::
Int J Radiat Res 2019, 17(3): 423-428 Back to browse issues page
Quantitative measurements for entrance and exit radiation dose confirmation for cancer patients: An analysis of large cohort of patients
M.A. Gadhi , N. Azeem , A. Azeem , S. Fatmi , A. Nazir , S.A. Buzdar
The University of Texas MD Anderson Cancer Center, Houston, Texas, USA , asghargadhi@gmail.com
Abstract:   (2955 Views)
Background: The success of radiation therapy depends on accurate dose delivery to the target. Diode in vivo measurement of entrance and exit dose is a valuable quality assurance (QA) tool to ensure accurate dose delivery.  Materials and Methods: This study was performed at BINO Cancer Hospital, Bahawalpur. Entrance and exit dose measurements were done with p-type diode for various types of cancer patients treated on Co-60 teletherapy unit. These measurements were compared with calculated (planned) dose values. A total of 3285 radiation fields of 723 cancer patients of various sites were included in current investigation. Results: The action level was ± 3 % for current measurements. The average percentage variation between the expected and measured dose was 0.37 with standard deviation 2.08. It was observed that 87.49 % of measurements were within tolerance level. It was also noticed that all dose deliveries fell within ± 5 %. This study showed that exit/wedged/oblique dose measurements were harder than entrance/non wedged/normal incidence dose measurements and more standard deviation were observed for these measurements. Conclusion: The Quantitative entrance and exit absorbed dose verification for cancer patients is beneficial for quality improvement in radiation therapy. A great majority of measurements were found within the acceptable limit. Execution of entrance and exit dose measurement procedure had demonstrated to be very helpful for detecting potential mistakes and avoiding errors due to accurate positioning of patients.
Keywords: Cancer, dose verification, quality improvement, Co-60 teletherapy.
Full-Text [PDF 1477 kb]   (1795 Downloads)    
Type of Study: Original Research | Subject: Radiation Biology
Send email to the article author

Add your comments about this article
Your username or Email:

CAPTCHA


XML     Print


Download citation:
BibTeX | RIS | EndNote | Medlars | ProCite | Reference Manager | RefWorks
Send citation to:

Gadhi M, Azeem N, Azeem A, Fatmi S, Nazir A, Buzdar S. Quantitative measurements for entrance and exit radiation dose confirmation for cancer patients: An analysis of large cohort of patients. Int J Radiat Res 2019; 17 (3) :423-428
URL: http://ijrr.com/article-1-2595-en.html


Rights and permissions
Creative Commons License This work is licensed under a Creative Commons Attribution-NonCommercial 4.0 International License.
Volume 17, Issue 3 (6-2019) Back to browse issues page
International Journal of Radiation Research
Persian site map - English site map - Created in 0.08 seconds with 50 queries by YEKTAWEB 4645