[Home ] [Archive]    
:: Main :: About :: Current Issue :: Archive :: Search :: Submit :: Contact ::
:: Volume 18, Issue 3 (7-2020) ::
Int J Radiat Res 2020, 18(3): 579-586 Back to browse issues page
Effect of lung inhomogeneity on dose distribution during radiotherapy of patient with lung cancer
M. Zabihzadeh Ph.D., , Z. Ghahremani, S.M. Hoseini, H. Shahbazian, M. Hoseini Ghahfarokhi
Cancer Research Center, Ahvaz Jundishapur University of Medical Sciences, Ahvaz, Iran. , manzabih@gmail.com
Abstract:   (662 Views)
Background: Presence of inhomogeneities such as lung tissue with low density can perturbs the dose distribution in the path of therapeutic photon beam and causes undesired cold or hot spots. The aim of this study was to investigate the effect of lung tissue inhomogeneities on dose distribution in thorax irradiation. Materials and Methods: The Monte Carlo simulation (MC) code of EGSnrc-based BEAMnrc was used to calculate dose distribution for 6 MV- Siemens Primus linear accelerator (Linac) in a homogenous phantom. Dose perturbation and inhomogeneity corrected factors (ICFs) were calculated due to implementation of lung tissue depended to the lung density and field size. Results: The maximum increased dose in lung tissue with lung density of 0.5 and 0.25gr/cm3 was 15.9%, 16.2%, 15.6%, 23.8 %, 24.8% and 25.0% for 6 × 6, 10 × 10 and 20 × 20 cm2 field sizes, respectively. The maximum ICF for these field sizes was 1.16 and 1.25 for lung density of 0.5 and 0.25gr/cm3, respectively. The maximum dose reduction in lung tissue with density of 0.25 and 0.5gr/cm3 was 19.5% and 4.2 %, and the related ICF was estimated 0.84 and 0.95, respectively. Conclusion: Involvement of lung tissue in the path of irradiation perturbs the dose distribution which is dependent to the lung density and field size. The ICFs resulted from our MC model could be useful to accurately calculate the dose distribution in radiotherapy of lung abnormalities.
Keywords: Electronic disequilibrium, lung cancer radiotherapy, Monte Carlo simulation, inhomogeneity correction factor.
Full-Text [PDF 2088 kb]   (129 Downloads)    
Type of Study: Original Research | Subject: Medical Physics
Send email to the article author

Add your comments about this article
Your username or Email:

CAPTCHA



XML     Print


Download citation:
BibTeX | RIS | EndNote | Medlars | ProCite | Reference Manager | RefWorks
Send citation to:

Zabihzadeh M, Ghahremani Z, Hoseini S, Shahbazian H, Hoseini Ghahfarokhi M. Effect of lung inhomogeneity on dose distribution during radiotherapy of patient with lung cancer. Int J Radiat Res. 2020; 18 (3) :579-586
URL: http://ijrr.com/article-1-3093-en.html


Volume 18, Issue 3 (7-2020) Back to browse issues page
International Journal of Radiation Research
Persian site map - English site map - Created in 0.05 seconds with 34 queries by YEKTAWEB 4212