Int J Radiat Res 2021, 19(1): 63-73 Back to browse issues page
Patient effective dose estimation for routine computed tomography examinations in Iran
M.R. Deevband , M. Ghorbani , A. Eshraghi , Y. Salimi , E. Saeedzadeh , M.R. Kardan , S. Sadeghi , D. Divband , M. Ahmadi
Biomedical Engineering and Medical Physics Department, School of Medicine, Shahid Beheshti University of Medical Sciences, Tehran, Iran. , Mdeevband@sbmu.ac.ir
Abstract:   (2256 Views)
Background: The present study intended to determine and report patient effective dose on the basis of patients and exposure data. Materials and methods: A nationwide computed tomography (CT) survey was provided as a report of patient doses in 2015-2016. Scan details were collected for nearly 2,000 adults and children in four age groups subjected to CT examinations. From total 565 CT scanners in different models in Iran, 120 different scanners were sampled. ImpactDose software was used to calculate the effective dose (ED) by collecting the necessary data also as an alternative fast method, the ED was estimated by multiplying dose length product (DLP) and a conversion factor. Results: There was a high variation in doses received by patients. The estimated EDs by the DLP and conversion factor were lower (except for sinus protocol) than those by ImpactDose software (p=0.014). The mean EDs were 1.09, 0.66, 7.70 and 13.29 mSv for adult patients’ procedures of head, sinus, chest and abdomen-pelvis, respectively. In terms of CTDIvol and DLP, in Iran the mean effective doses were significantly lower than other countries. Conclusion: Publishing guidelines and exposure tables according to patient situations is necessary to decrease variations in doses and exposure parameters. Since the DLP conversion factor leads to a considerable discrepancy in calculating ED, when there is a need for precise dose calculations, the DLP conversion factor should not be used. Furthermore, it is suggested that ED be used as DRL, instead of CTDIvol.
Keywords: Effective dose estimation, CTDI, DLP, impact dose software.
Full-Text [PDF 1773 kb]   (1005 Downloads)    
Type of Study: Original Research | Subject: Medical Physics
Send email to the article author

Add your comments about this article
Your username or Email:

CAPTCHA



XML     Print


Download citation:
BibTeX | RIS | EndNote | Medlars | ProCite | Reference Manager | RefWorks
Send citation to:

Deevband M, Ghorbani M, Eshraghi A, Salimi Y, Saeedzadeh E, Kardan M, et al . Patient effective dose estimation for routine computed tomography examinations in Iran. Int J Radiat Res 2021; 19 (1) :63-73
URL: http://ijrr.com/article-1-3457-en.html


Rights and permissions
Creative Commons License This work is licensed under a Creative Commons Attribution-NonCommercial 4.0 International License.
Volume 19, Issue 1 (1-2021) Back to browse issues page
International Journal of Radiation Research
Persian site map - English site map - Created in 0.05 seconds with 50 queries by YEKTAWEB 4660