[Home ] [Archive]    
:: Main :: About :: Current Issue :: Archive :: Search :: Submit :: Contact ::
Main Menu
Home::
IJRR Information::
For Authors::
For Reviewers::
Subscription::
News & Events::
Web Mail::
::
Search in website

Advanced Search
..
Receive site information
Enter your Email in the following box to receive the site news and information.
..
ISSN
Hard Copy 2322-3243
Online 2345-4229
..
Online Submission
Now you can send your articles to IJRR office using the article submission system.
..

AWT IMAGE

AWT IMAGE

Volume 20, Issue 1 (1-2022)                   Int J Radiat Res 2022, 20(1): 229-233 | Back to browse issues page


XML Print


Download citation:
BibTeX | RIS | EndNote | Medlars | ProCite | Reference Manager | RefWorks
Send citation to:

Bahtijari M, Nafezi G, Hodolli G, Kadiri S. Radon activity assessment of thermal water in Spas of Kosovo by using different methods. Int J Radiat Res 2022; 20 (1) :229-233
URL: http://ijrr.com/article-1-4102-en.html
University of Prishtina “Hasan Prishtina”, Faculty of Mathematics and Natural Sciences, Department of Physics, Prishtina, Kosovo , gazmend.nafezi@gmail.com
Abstract:   (2467 Views)
Background: Exposure to radon and radon decay products at home and at workplaces constitutes one of the greatest and perhaps the greatest risk from ionizing radiation. In this study, radon activity concentrations were measured in thermal water, spring water, in the water of baths/pools, and indoor air of five spas in Kosovo. Materials and Methods: Different comparison active methods were used and also the long-term measurements were performed. Results: The radon activity concentrations were found to be 23 Bq l-1 to 314 Bq l-1 in water coming from a thermal source, 13 Bq l-1 to 270 Bq l-1 in water of baths, 25 Bq l-1 to 108 Bq l-1, in water of pools and 16 Bq l-1 to 67 Bq l-1 in taps water. The indoor radon concentrations and soil gas measurements near the thermal spas has range from 24 Bq m-3 to 506 Bq m-3 respectively from 4978 Bq m-3 to 67249 Bq m-3. Conclusions: The indoor air radon concentrations in workrooms, baths, and pools only in one case exceeded 500 Bq m-3. The reason of high indoor radon concentration could have been the location of this room, located near the baths and pool of spa. The maximum radon activity concentration in taps water is the only that did not exceed the limit from 100 Bq l-1.
 
Full-Text [PDF 1532 kb]   (1318 Downloads)    
Type of Study: Short Report | Subject: Radiobiology

Add your comments about this article : Your username or Email:
CAPTCHA

Send email to the article author


Rights and permissions
Creative Commons License This work is licensed under a Creative Commons Attribution-NonCommercial 4.0 International License.

International Journal of Radiation Research
Persian site map - English site map - Created in 0.09 seconds with 50 queries by YEKTAWEB 4718