Abstract:   (175 Views)
Background: Various developed intensity modulated radiation therapy (IMRT) and a three dimensional conformal radiation therapy (3D-CRT) protocols were assessed for treating nasopharyngeal cancer (NPC) based on radiobiological parameters. Materials and Methods: Treatment plans were made for 30 NPC patients using 15 developed IMRT and 3D-CRT protocols. The IMRT protocols comprised of three 7-fields with various collimator (0°, 5°, and 10°) and couch (0°, 4°, 8°, 12°) angles. The 3D-CRT technique included two phases. In the 1st phase a dose of 60 Gy was prescribed to the total PTV, but in the 2nd phase a dose of 10 Gy was prescribed to the PTV-70. The tumour control probability (TCP), normal tissues complication probability (NTCP), and complication-free tumor control probability (P+) parameters were estimated for assessing the IMRT protocols. Then, the ideal protocol (s) were proposed through comparing the IMRT protocols with each other and 3D-CRT protocol based on TCP, NTCP, and P+ values. Results: The IMRT protocol with 10° collimator and 8° couch angles had the lowest NTCP mean values. Significant differences were observed among the mean NTCP values for the brainstem and parotid glands, and P+ of the developed IMRT and 3D-CRT protocols. However, no significant differences were observed among the mean NTCP values for the spinal cord, optic chiasm and optic nerves among the protocols. Conclusions: The 3D-CRT protocol had a good outcome for the NPC patients having a lower common volume between their total planning target volume and OARs, while the results of the IMRT showed the opposite.
 
 
Keywords: Nasopharyngeal carcinoma, intensity modulated radiation therapy, 3D radiation therapy, treatment planning, radiobiological models.
Full-Text [PDF 1817 kb]   (109 Downloads)    
Type of Study: Original Research | Subject: Radiation Biology
Send email to the article author

Add your comments about this article
Your username or Email:

CAPTCHA



XML     Print


Download citation:
BibTeX | RIS | EndNote | Medlars | ProCite | Reference Manager | RefWorks
Send citation to:

Sharbo G, Hashemi B, Bakhshandeh M, Rakhsha A. Assessment of developed IMRT and 3D-CRT planning protocols for treating nasopharyngeal cancer patients based on the target and organs at risks common volumes. Int J Radiat Res. 2022; 20 (2) :307-315
URL: http://ijrr.com/article-1-4259-en.html


Rights and permissions
Creative Commons License This work is licensed under a Creative Commons Attribution-NonCommercial 4.0 International License.
Volume 20, Issue 2 (4-2022) Back to browse issues page
International Journal of Radiation Research
Persian site map - English site map - Created in 0.06 seconds with 32 queries by YEKTAWEB 4414