[Home ] [Archive]    
:: Main :: About :: Current Issue :: Archive :: Search :: Submit :: Contact ::
Main Menu
Home::
IJRR Information::
For Authors::
For Reviewers::
Subscription::
News & Events::
Web Mail::
::
Search in website

Advanced Search
..
Receive site information
Enter your Email in the following box to receive the site news and information.
..
ISSN
Hard Copy 2322-3243
Online 2345-4229
..
Online Submission
Now you can send your articles to IJRR office using the article submission system.
..

AWT IMAGE

AWT IMAGE

:: Volume 20, Issue 2 (4-2022) ::
Int J Radiat Res 2022, 20(2): 317-322 Back to browse issues page
Voxel-based dose calculation of radionuclide imaging and therapy for preclinical studies using GEANT4 Monte Carlo simulation
H. Liu , C. Geng , X. Tang , L. Tang , X. Li , P. Xu
Department of Nuclear Science and Technology Nanjing University of Aeronautics and Astronautics,29 General Road, Jiangning District, Nanjing 211106, China , gengchr@nuaa.edu.cn
Abstract:   (997 Views)
Background: This study aims to investigate voxel-level dose calculation methods and improve its calculation efficiency in nuclear medicine that can consider animal-specific heterogeneous tissue compositions and radiopharmaceutical biodistributions simultaneously. Materials and Methods: The voxelized mouse phantom was constructed from real mouse CT images and simulated using the Monte Carlo GEANT4 code. According to the dynamic PET images of real mouse, the real distribution of radiopharmaceutical activity was set in the Monte Carlo simulation. The sampling method to improve the calculation efficiency was proposed. Two voxel-level dose calculation methods were implemented in this study. The average absorbed dose in vital target organs and the tumor was calculated by the proposed voxel-level dose calculation methods and the traditional MIRD method respectively. The results of the average absorbed dose calculated by the two methods were compared. Based on the voxel-level dose calculation method, the three-dimensional dose distribution in organs and the tumor was obtained and evaluated. Results: The relative difference of average absorbed dose between the two voxel-level dose calculation methods was mostly less than 10%. The sampling method proposed to improve calculation efficiency for the voxel-level dose calculation can decrease the calculation time by ~34% with less deviation. Conclusion: The results confirmed that the voxel-level dose calculation methods proposed in this study allow for more accurate and efficient assessment of the internal radiation dose.
 
 
Keywords: Internal dosimetry, radiopharmaceutical, Monte Carlo simulation, MIRD.
Full-Text [PDF 1699 kb]   (567 Downloads)    
Type of Study: Original Research | Subject: Radiation Biology
Send email to the article author

Add your comments about this article
Your username or Email:

CAPTCHA



XML     Print


Download citation:
BibTeX | RIS | EndNote | Medlars | ProCite | Reference Manager | RefWorks
Send citation to:

Liu H, Geng C, Tang X, Tang L, Li X, Xu P. Voxel-based dose calculation of radionuclide imaging and therapy for preclinical studies using GEANT4 Monte Carlo simulation. Int J Radiat Res 2022; 20 (2) :317-322
URL: http://ijrr.com/article-1-4260-en.html


Rights and permissions
Creative Commons License This work is licensed under a Creative Commons Attribution-NonCommercial 4.0 International License.
Volume 20, Issue 2 (4-2022) Back to browse issues page
International Journal of Radiation Research
Persian site map - English site map - Created in 0.05 seconds with 50 queries by YEKTAWEB 4645