Department of Radiology, Affiliated Second Hospital, Dalian Medicial University, Dalian 116000, People's Republic of China , drshalin@163.com
Abstract: (1207 Views)
The high incidence of intracranial aneurysms and the high mortality rate after rupture highlight the requirement and importance for early and accurate visualization of the aneurysm profile for subsequent patient treatment. Here we report a patient with an intracranial aneurysm who underwent digital subtraction angiography (DSA), zero echo time MRA (ZTE-MRA), and three-dimensional time-of-flight MRA (3D-TOF-MRA) on admission and after operation. The imaging quality and accuracies of ZTE-MRA and 3D-TOF-MRA were compared with DSA, the gold standard, in pre-operative and post-operative evaluation of intracranial aneurysms.Comparison of the two MRAs, ZTE-MRA has greater advantages in imaging.
1. 1. Liu Z, Ajimu K, Yalikun N, Zheng Y, Xu F (2019) Potential therapeutic strategies for intracranial aneurysms targeting aneurysm pathogenesis. Front Neurosci, 13: 1238. [DOI:10.3389/fnins.2019.01238] [PMID] []
2. Marbacher S, Halter M, Vogt DR, et al. (2021) Value of 3-dimensional digital subtraction angiography for detection and classification of intracranial aneurysm remnants after clipping. Oper Neurosurg (Hagerstown), 21(2): 63-72. [DOI:10.1093/ons/opab087] [PMID] []
3. Gottwald LM, Toger J, Markenroth Bloch K, et al. (2020) High Spatiotemporal Resolution 4D Flow MRI of Intracranial Aneurysms at 7T in 10 Minutes. AJNR Am J Neuroradiol, 41(7): 1201-8. [DOI:10.3174/ajnr.A6603] [PMID] []
4. Howard BM, Hu R, Barrow JW, Barrow DL (2019) Comprehensive review of imaging of intracranial aneurysms and angiographically negative subarachnoid hemorrhage. Neurosurg Focus, 47(6): E20. [DOI:10.3171/2019.9.FOCUS19653] [PMID]
5. Zhu C, Wang X, Eisenmenger L, et al. (2019) Surveillance of unruptured intracranial saccular aneurysms using noncontrast 3D-black-blood MRI: Comparison of 3D-TOF and contrast-enhanced MRA with 3D-DSA. AJNR Am J Neuroradiol, 40(6): 960-6. [DOI:10.3174/ajnr.A6080] [PMID] []
6. Igase K, Igase M, Matsubara I, Sadamoto K (2018) Mismatch between TOF MR angiography and CT angiography of the middle cerebral artery may be a critical sign in cerebrovascular dynamics. Yonsei Med J, 59(1): 80-4. [DOI:10.3349/ymj.2018.59.1.80] [PMID] []
7. Shang S, Ye J, Luo X, Qu J, Zhen Y, Wu J (2017) Follow-up assessment of coiled intracranial aneurysms using zTE MRA as compared with TOF MRA: a preliminary image quality study. Eur Radiol, 27(10): 4271-80. [DOI:10.1007/s00330-017-4794-z] [PMID]
8. Song Y, Qi P, Huang J, et al. (2020) Application of zero echo time MR angiography in follow-up of intracranial aneurysm remnant and in-stent lumen after embolization: a comparison study with digital subtraction angiography. Acta Radiol, 61(4): 480-6. [DOI:10.1177/0284185119865721] [PMID]
9. Marciano D, Soize S, Metaxas G, Portefaix C, Pierot L (2017) Follow-up of intracranial aneurysms treated with stent-assisted coiling: Comparison of contrast-enhanced MRA, time-of-flight MRA, and digital subtraction angiography. J Neuroradiol, 44(1): 44-51. [DOI:10.1016/j.neurad.2016.10.004] [PMID]
10. Shang S, Ye J, Dou W, et al. (2019) Validation of Zero TE-MRA in the Characterization of Cerebrovascular Diseases: A Feasibility Study. AJNR Am J Neuroradiol, 40(9): 1484-90. [DOI:10.3174/ajnr.A6173] [PMID] []
11. Wu H, Block WF, Turski PA, Mistretta CA, Johnson KM (2013) Noncontrast-enhanced three-dimensional (3D) intracranial MR angiography using pseudocontinuous arterial spin labeling and accelerated 3D radial acquisition. Magn Reson Med, 69(3): 708-15. [DOI:10.1002/mrm.24298] [PMID] []
Lyu J, Sha L, Qi X, Chen Z. Evaluation of intracranial aneurysm: Comparison between ZTE-MRA and 3D-TOF-MRA. Int J Radiat Res 2022; 20 (3) :723-725 URL: http://ijrr.com/article-1-4395-en.html