[Home ] [Archive]    
:: Main :: About :: Current Issue :: Archive :: Search :: Submit :: Contact ::
Main Menu
Home::
IJRR Information::
For Authors::
For Reviewers::
Subscription::
News & Events::
Web Mail::
::
Search in website

Advanced Search
..
Receive site information
Enter your Email in the following box to receive the site news and information.
..
ISSN
Hard Copy 2322-3243
Online 2345-4229
..
Online Submission
Now you can send your articles to IJRR office using the article submission system.
..

AWT IMAGE

AWT IMAGE

:: Volume 23, Issue 1 (1-2025) ::
Int J Radiat Res 2025, 23(1): 233-238 Back to browse issues page
A meta-analysis examining the risk factors associated with pneumothorax during CT-guided percutaneous lung biopsy
J. Xiaoxing , W. Dongnv , W. Yitian , M. Ling , J. Wenbin , Y. Shuzong
Department of Radiology, Taizhou Hospital of Zhejiang Province Affiliated to Wenzhou Medical University, Linhai, Zhejiang, China , wb.j@163.com
Abstract:   (319 Views)
Background: The study aimed to systematically evaluate the risk factors for pneumothorax after computed tomography (CT)-guided percutaneous lung biopsy. Materials and Methods: We conducted a search of several databases, including PubMed, Embase, the Cochrane Library, Web of Science, and CNKI, until May 2021, focusing on research related to risk factors for pneumothorax following CT-guided percutaneous lung biopsy. After screening and extracting the data, we conducted a meta-analysis using RevMan software (version 5.3) to calculate the odds ratio (OR) and 95% confidence interval (CI) for each relevant risk factor. Statistical significance was set at P<0.05. Results: Our study included 28 articles and 16,667 patients who underwent CT-guided lung biopsy, of whom 4,566 patients developed pneumothorax (27.40%). Our results showed that the incidence of pneumothorax was lower in the group with pulmonary nodules ≥ 2 cm, and the difference was statistically significant (OR=0.61, 95% CI=0.43–0.86, P=0.004). Additionally, patients with emphysema had a higher risk of developing a pneumothorax after the procedure, and the difference was statistically significant (OR=2.5, 95% CI=1.62–3.87, P<0.0001). Correlation analysis of sex, lung nodule size, needle track length, and CT-guided lung nodule biopsy showed no significant differences (P>0.05). Conclusion: Our findings indicate that pulmonary nodules smaller than 2 cm and emphysema significantly increase the risk of pneumothorax after puncture. Clinicians should be vigilant in monitoring patients with these risk factors after the procedure.
Keywords: CT-guided percutaneous lung biopsy, pulmonary nodules, pneumothorax, risk factors, meta-analysis.
Full-Text [PDF 727 kb]   (46 Downloads)    
Type of Study: Original Research | Subject: Radiation Biology
References
1. 1. Cruickshank A, Stieler G, Ameer F (2019) Evaluation of the solitary pulmonary nodule. Int Med J, 49(3): 306-315. [DOI:10.1111/imj.14219]
2. Ettinger DS, Wood DE, Aisner DL, et al. (2021) NCCN Guidelines insights: Non-small cell lung cancer, Version 2.2021. J Natl Compr Canc Netw (1540-1413 (Electronic)).
3. Liu J, Wu Y, Liang C, et al. (2019) The study of C-arm CT guided percutaneous transthoracic biopsy of lung nodules. Journal of Clinical Radiology, 3(4): 534-537.
4. Flagg ER, Henry TS, Elicker BM, Kallianos KG, Ordovas KG, Naeger DM (2018) Periprocedural management in transthoracic needle biopsy: review of the current evidence. Curr Radiol Rep, 6(4): doi.org/10.1007/s40134-018-0274-8 [DOI:10.1007/s40134-018-0274-8]
5. Ruth HY, Vinchill CM, Al-Rahim H, Isaac L, Lloyd R (2020) Pneumothorax rates in CT-Guided lung biopsies: a comprehensive systematic review and meta-analysis of risk factors. Br J Radiol, 93(1108): 20190866. [DOI:10.1259/bjr.20190866]
6. He C, Li Y, Yang L, et al. (2017) Pneumorrhagia and pneumothorax occurring after CT-guided cutting needle biopsy for pulmonary solid nodules: a multivariate analysis. Journal of Interventional Radiology, 7(6): 654-659.
7. Wang L, Dong H, Bai B, et al. (2020) Diagnostic accuracy and analysis of complication related factors of CT-guided percutaneous core needle biopsy of pulmonary nodules of different sizes. Radiology Practice, 11(6): 1409-1414.
8. Ashraf H, Krag-Andersen S, Naqibullah M, et al. (2017) Computed tomography guided lung biopsy using interactive breath-hold control: a randomized study. Ann Transl Med, 5(12): 253. [DOI:10.21037/atm.2017.05.10]
9. Halit BF, Remzi A, Levent K, et al. (2011) The results of computed tomography guided tru-cut transthoracic biopsy: complications and related risk factors. Wien Klin Wochenschr, 123(3-4): 79-82. [DOI:10.1007/s00508-011-1538-y]
10. Brandén E, Wallgren S, Högberg H, Koyi H (2014) Computed tomography-guided core biopsies in a county hospital in Sweden: Complication rate and diagnostic yield. Ann Thorac Med, 9(3): 149-53. [DOI:10.4103/1817-1737.134069]
11. Chakrabarti B, Earis JE, Pandey R, et al. (2009) Risk assessment of pneumothorax and pulmonary haemorrhage complicating percutaneous co-axial cutting needle lung biopsy. Respir Med, 103(3): 449-55. [DOI:10.1016/j.rmed.2008.09.010]
12. Covey AM, Gandhi R, Brody LA, Getrajdman G, Thaler HT, Brown KT (2004) Factors associated with pneumothorax and pneumothorax requiring treatment after percutaneous lung biopsy in 443 consecutive patients. J Vasc Interv Radiol, 15(5): 479-83. [DOI:10.1097/01.RVI.0000124951.24134.50]
13. Drumm O, Joyce EA, de Blacam C, et al. (2019) CT-guided lung biopsy: Effect of biopsy-side down position on pneumothorax and chest tube placement. Radiology, 292(1): 190-196. [DOI:10.1148/radiol.2019182321]
14. Geraghty PR, Kee ST, McFarlane G, Razavi MK, Sze DY, Dake MD (2003) CT-guided transthoracic needle aspiration biopsy of pulmonary nodules: needle size and pneumothorax rate. Radiology, 229(2): 475-81. [DOI:10.1148/radiol.2291020499]
15. Hiraki T, Mimura H, Gobara H, et al. (2010) Incidence of and risk factors for pneumothorax and chest tube placement after CT fluoroscopy-guided percutaneous lung biopsy: retrospective analysis of the procedures conducted over a 9-year period. Am J Roentgenol, 194(3): 809-14. [DOI:10.2214/AJR.09.3224]
16. Khan MF, Straub R, Moghaddam SR, et al. (2008) Variables affecting the risk of pneumothorax and intrapulmonal hemorrhage in CT-guided transthoracic biopsy. Eur Radiol, 18(7): 1356-63. [DOI:10.1007/s00330-008-0893-1]
17. Kim JI, Park CM, Lee SM, Goo JM (2015) Rapid needle-out patient-rollover approach after cone beam CT-guided lung biopsy: effect on pneumothorax rate in 1,191 consecutive patients. Eur Radiol, 25(7): 1845-53. [DOI:10.1007/s00330-015-3601-y]
18. Kolderman NC, Cheti DR, Hasbrook CD, et al. (2020) Pneumothorax rate and diagnostic adequacy of computed tomography-guided lung nodule biopsies performed with 18 G Versus 20 G needles: A cross-sectional study. J Thorac Imaging, 35(4): 265-269. [DOI:10.1097/RTI.0000000000000481]
19. 19 Kuban JD, Tam AL, Huang SY, et al. (2015) The effect of needle gauge on the risk of pneumothorax and chest tube placement after percutaneous computed tomographic (CT)-guided lung biopsy. Cardiovasc Intervent Radiol, 38(6): 1595-602. [DOI:10.1007/s00270-015-1097-0]
20. Lee HY and Lee IJ (2016) Assessment of independent risk factors of developing pneumothorax during percutaneous core needle lung biopsy: focus on lesion depth. Iran J Radiol, 13(4): e30929. [DOI:10.5812/iranjradiol.30929]
21. Min LS, Min PC, Hee LK, Eun BY, Im KJ, Mo GJ (2014) C-arm cone-beam CT-guided percutaneous transthoracic needle biopsy of lung nodules: clinical experience in 1108 patients. Radiology, 271(1): 291-300. [DOI:10.1148/radiol.13131265]
22. Loubeyre P, Copercini M, Dietrich PY (2005) Percutaneous CT-guided multisampling core needle biopsy of thoracic lesions. Am J Roentgenol, 185(5): 1294-8. [DOI:10.2214/AJR.04.1344]
23. Noh TJ, Lee CH, Kang YA, et al. (2009) Chest computed tomography (CT) immediately after CT-guided transthoracic needle aspiration biopsy as a predictor of overt pneumothorax. Korean J Intern Med, 24(4): 343-9. [DOI:10.3904/kjim.2009.24.4.343]
24. Ozturk K, Soylu E, Gokalp G, Topal U (2018) Risk factors of pneumothorax and chest tube placement after computed tomography-guided core needle biopsy of lung lesions: a single-centre experience with 822 biopsies. Pol J Radiol, 83: e407-e414. [DOI:10.5114/pjr.2018.79205]
25. Patel Mikin V, Osman A, Danial J, Steve Z (2014) Computed tomography-guided percutaneous lung biopsy: impact of lesion proximity to diaphragm on biopsy yield and pneumothorax rate. J Thorac Imaging, 29(6): 344-349. [DOI:10.1097/RTI.0000000000000112]
26. Rong E, Hirschl DA, Zalta B, et al. (2021) A retrospective multi-site academic center analysis of pneumothorax and associated risk factors after CT-guided percutaneous lung biopsy. Lung, 199(3): 299-305. [DOI:10.1007/s00408-021-00445-7]
27. Ruud EA, Stavem K, Geitung JT, Borthne A, Søyseth V, Ashraf H (2021) Predictors of pneumothorax and chest drainage after percutaneous CT-guided lung biopsy: A prospective study. Eur Radiol, 31(6): 4243-4252. [DOI:10.1007/s00330-020-07449-6]
28. Sabatino V, Russo U, D'Amuri F, et al. (2021) Pneumothorax and pulmonary hemorrhage after CT-guided lung biopsy: incidence, clinical significance and correlation. Radiol Med, 126(1): 170-177. [DOI:10.1007/s11547-020-01211-0]
29. Weon J, Robson S, Chan R, Ussher S (2021) Development of a risk prediction model of pneumothorax in percutaneous computed tomography guided transthoracic needle lung biopsy. J Med Imaging Radiat Oncol, 65(6): 686-693. [DOI:10.1111/1754-9485.13187]
30. Chen S, Qu K, Zhang Z, et al. (2021) Diagnostic value of CT-guided lung biopsy for patients with early solitary pulmonary nodule and the nomogram model of postoperative hemoptysis risk prediction (Chinese journal), Practical Journal of Cardiac Cerebral Pneumal and Vascular Disease, 7(7): 68-73.
31. Xiao F and Yang B (2018) CT-guided percutaneous pulmonary puncture for diagnosis of peripheral nodular lesions and related factors of complications (Chinese Journal). Journal of Modern Oncology, 23(5): 3772-3776.
32. Yan G, Yang G, Fu Q, et al. (2017) Failure factor analysis of CT guided PTNB for fGGN in diagnosis. Journal of North Sichuan Medical College, 5(4): 684-687.
33. You Y, Wang P, Kuang J, et al. (2021) Application experience of image-guided percutaneous biopsy of thoracic masses. Journal of Clinical Radiology, 9(4): 1790-1793.
34. Laurent F, Latrabe V, Vergier B, Montaudon M, Vernejoux JM, Dubrez J (2000) CT-guided transthoracic needle biopsy of pulmonary nodules smaller than 20 mm: results with an automated 20-gauge coaxial cutting needle. Clin Radiol, 55(4): 281-7. [DOI:10.1053/crad.1999.0368]
35. Yeow KM, Tsay PK, Cheung YC, et al. (2003) Factors affecting diagnostic accuracy of CT-guided coaxial cutting needle lung biopsy: retrospective analysis of 631 procedures. J Vasc Interv Radiol, 14(5):581-588. [DOI:10.1097/01.RVI.0000071087.76348.C7]
Send email to the article author

Add your comments about this article
Your username or Email:

CAPTCHA


XML     Print


Download citation:
BibTeX | RIS | EndNote | Medlars | ProCite | Reference Manager | RefWorks
Send citation to:

Xiaoxing J, Dongnv W, Yitian W, Ling M, Wenbin J, Shuzong Y. A meta-analysis examining the risk factors associated with pneumothorax during CT-guided percutaneous lung biopsy. Int J Radiat Res 2025; 23 (1) :233-238
URL: http://ijrr.com/article-1-6062-en.html


Rights and permissions
Creative Commons License This work is licensed under a Creative Commons Attribution-NonCommercial 4.0 International License.
Volume 23, Issue 1 (1-2025) Back to browse issues page
International Journal of Radiation Research
Persian site map - English site map - Created in 0.11 seconds with 50 queries by YEKTAWEB 4704