[Home ] [Archive]    
:: Main :: About :: Current Issue :: Archive :: Search :: Submit :: Contact ::
:: Volume 12, Issue 4 (10-2014) ::
Int J Radiat Res 2014, 12(4): 355-359 Back to browse issues page
Dose measurement outside of radiotherapy treatment field (Peripheral dose) using thermoluminesent dosimeters
N. Banaee, H.A. Nedaie , E. Esmati, H. Nosrati, M. Jamali
Radiotherapy Oncology Department, Cancer research Centre, Tehran University of Medical Sciences, Tehran, Iran , Nedaieha@sina.tums.ac.ir
Abstract:   (6199 Views)

Background: In radiation therapy, peripheral dose or the dose outside the radiotherapy field, is important when anatomical structures with very low dose tolerances are involved. One of these critical organs in pelvic irradiation is testis. The amount of radiation delivered to the testes in radiotherapy must be kept as small as possible, consistent with the limit dose of this organ. The threshold doses for temporary and permanent sterility are 0.15 Gy and 6-8 Gy, respectively. Therefore, in pelvic irradiation, protecting testis from these doses and also scattered radiation which could escalate testis dose should be considered. Materials and Methods: In order to determine the possibility of using testicular shield for high and low energies, TLD dosimetry was done on phantom and 27 patients involved with bladder, rectum and prostate cancers. Results: Dosimetric results showed that the ability of testicular shield in reducing testes absorbed dose is approximately the same (about 7 cGy) for low and high energy photon beams. Conclusion: a testicular shield with a fixed thickness of 1.27cm can be used as testis protection for either high and low energies.

Keywords: Testicular shield, pelvic irradiation, peripheral dose
Full-Text [PDF 386 kb]   (1605 Downloads)    
Type of Study: Original Research | Subject: Radiation Biology
Send email to the article author

Add your comments about this article
Your username or Email:

CAPTCHA


XML     Print


Download citation:
BibTeX | RIS | EndNote | Medlars | ProCite | Reference Manager | RefWorks
Send citation to:

Banaee N, Nedaie H, Esmati E, Nosrati H, Jamali M. Dose measurement outside of radiotherapy treatment field (Peripheral dose) using thermoluminesent dosimeters. Int J Radiat Res. 2014; 12 (4) :355-359
URL: http://ijrr.com/article-1-1355-en.html


Rights and permissions
Creative Commons License This work is licensed under a Creative Commons Attribution-NonCommercial 4.0 International License.
Volume 12, Issue 4 (10-2014) Back to browse issues page
International Journal of Radiation Research
Persian site map - English site map - Created in 0.04 seconds with 32 queries by YEKTAWEB 4343