:: Volume 16, Issue 4 (10-2018) ::
Int J Radiat Res 2018, 16(4): 499-503 Back to browse issues page
Assessment of skyshine photon dose rates from 9 and 18 MV medical linear accelerators
N. Rostampour , S. Jafari , M. Saeb , M. Keshtkar , P. Shokrani , T. Almasi
Department of Medical Physics, Kermanshah University of Medical Sciences, Kermanshah, Iran , nima.rostampour@kums.ac.ir
Abstract:   (3255 Views)
Background: Skyshine describes the radiation scattered by the atmosphere above a LINAC facility to a point on the ground. The aim of this study was to measure the skyshine photon dose rates from two different (9 MV and 18 MV) medical linear accelerators. Materials and Methods: The photon beam was directed upward (180° gantry position), with a maximum photon field size (40 × 40 cm2) at the isocenter. Measurements were obtained around the external points selected outside the room facilities at a horizontal distance from the target by the calibrated RDS-110 survey meter at four points around the isocenter. Results: The measured values of the skyshine photon exposure rates at four points for 9 MV and 18 MV were 0.6, 0.5, 0.5, and 0.4 μSv/h, and 0.6, 0.4, 0.4, and 0.5 μSv/h, respectively. All the measured skyshine photon exposure rates were lower than the values recommended by NCRP 147. Conclusion: There is a poor agreement between the measured and the calculated values; therefore it seems that caution is needed while using the equations available in NCRP 147 or 151.
Keywords: Skyshine, shielding, radiation measurement, radiation protection, radiotherapy, scattering, medical accelerator.
Full-Text [PDF 1772 kb]   (1962 Downloads)    
Type of Study: Technical Note | Subject: Radiation Biology
Send email to the article author

Add your comments about this article
Your username or Email:

CAPTCHA


XML     Print


Download citation:
BibTeX | RIS | EndNote | Medlars | ProCite | Reference Manager | RefWorks
Send citation to:

Rostampour N, Jafari S, Saeb M, Keshtkar M, Shokrani P, Almasi T. Assessment of skyshine photon dose rates from 9 and 18 MV medical linear accelerators . Int J Radiat Res 2018; 16 (4) :499-503
URL: http://ijrr.com/article-1-2405-en.html


Rights and permissions
Creative Commons License This work is licensed under a Creative Commons Attribution-NonCommercial 4.0 International License.
Volume 16, Issue 4 (10-2018) Back to browse issues page
International Journal of Radiation Research
Persian site map - English site map - Created in 0.05 seconds with 50 queries by YEKTAWEB 4645