:: Volume 17, Issue 2 (4-2019) ::
Int J Radiat Res 2019, 17(2): 189-202 Back to browse issues page
Methods to evaluate the performance of kilovoltage cone-beam computed tomography in the three-dimensional reconstruction space
J. Zhang , Z.R. Bao , X.T. Huang , D.Z. Jiang , C.H. Xie , Y.F. Zhou , H. Liu
Department of Radiation and Medical Oncology, Zhongnan Hospital of Wuhan University; and Hubei Radiotherapy Quality Control Center, Wuhan University, Hubei, China , liuhui69_wh@hotmail.com
Abstract:   (4228 Views)
Background: Cone-beam computed tomography (CBCT) scanners for image-guided radiotherapy are in clinical use today, but there has been no consensus on uniform acceptance to verify the CBCT image quality yet. The present work proposed new methods to fully evaluate the performance of CBCT in its three-dimensional (3D) reconstruction space. Materials and Methods: Compared to the traditional methods with only two-dimensional axial slice evaluated, the new methods were designed to evaluate the CBCT image quality not only in the axial slices but also along three dimensions and three sections. Image parameters were evaluated by scanning the corresponding phantom. Results: The new methods demonstrated the high spatial resolution, the image uniformity, the high CT numbers linearity, geometric accuracy and relatively poor performance in low contrast resolution, compared to the results of plan CT. Additionally, the spatial resolution, the CT number linearity and the image uniformity proved to be more superior along the z direction and in the cross-section. Furthermore, the spatial resolution and the CT value linearity decreased gradually when deviating from the center of rotation axis and accelerates the reduction towards the periphery area, suggesting that locating the target within the range of 4 cm around the isocenter during radiotherapy ensure the optimal spatial resolution and the CT value linearity.  Conclusion: Results indicate that the proposed three-dimensional image quality evaluation holds the potential to complement existing standards to provide sufficient information for the CBCT image performance and thereby guiding the clinical applications of CBCT. 
Keywords: Image quality, CBCT, three-dimensional.
Full-Text [PDF 2426 kb]   (2130 Downloads)    
Type of Study: Original Research | Subject: Radiation Biology
Send email to the article author

Add your comments about this article
Your username or Email:

CAPTCHA


XML     Print


Download citation:
BibTeX | RIS | EndNote | Medlars | ProCite | Reference Manager | RefWorks
Send citation to:

Zhang J, Bao Z, Huang X, Jiang D, Xie C, Zhou Y et al . Methods to evaluate the performance of kilovoltage cone-beam computed tomography in the three-dimensional reconstruction space. Int J Radiat Res 2019; 17 (2) :189-202
URL: http://ijrr.com/article-1-2494-en.html


Rights and permissions
Creative Commons License This work is licensed under a Creative Commons Attribution-NonCommercial 4.0 International License.
Volume 17, Issue 2 (4-2019) Back to browse issues page
International Journal of Radiation Research
Persian site map - English site map - Created in 0.05 seconds with 50 queries by YEKTAWEB 4645