[Home ] [Archive]    
:: Main :: About :: Current Issue :: Archive :: Search :: Submit :: Contact ::
Main Menu
Home::
IJRR Information::
For Authors::
For Reviewers::
Subscription::
News & Events::
Web Mail::
::
Search in website

Advanced Search
..
Receive site information
Enter your Email in the following box to receive the site news and information.
..
ISSN
Hard Copy 2322-3243
Online 2345-4229
..
Online Submission
Now you can send your articles to IJRR office using the article submission system.
..

AWT IMAGE

AWT IMAGE

:: Volume 17, Issue 2 (4-2019) ::
Int J Radiat Res 2019, 17(2): 335-344 Back to browse issues page
Quantification and modelling of the dosimetric impact of the treatment couch in volumetric modulated arc therapy (VMAT)
R.H. Zhang , J. Fleckenstein , Y.L. Gao , M.C. Miao , Z.F. Chi , W.W. Bai
Department of Radiotherapy, The Fourth Hospital of Hebei Medical University, Shijiazhuang, China , baiwenwen2006@126.com
Abstract:   (3469 Views)
Background: As the volumetric modulated arc therapy (VMAT) becoming a main role of treatment ways, the effect of couch top becomes more significant. It is imperative to re-evaluate the couches that previously may have been considered of no importance during early treatment techniques. The impact of couch top on radiation delivery was explored and the couch model was tested with the aim of reducing the couch absorption influences.  Materials and Methods: Attenuation measurements were performed in a cylindrical phantom with an ionization chamber positioned at the isocenter. Couch model was obtained by importing its actual CT scan, and the accuracy was evaluated by comparing percentage deviation at 2 and 5 mm voxel grid size. Effects on surface dose were measured using EBT3 film with the constant SSD at different depths and beam energies at the gantry angle 180° and 0°, respectively. Results: Couch top increases surface dose from 45.9 % to 95.8 % , from 35.0 % to 87.9 % and from 29.2% to 73.9 % for 10 cm ×10 cm field at 6 ,10 and 18 MV, respectively. Due to the couch absorption the case of vertebral metastasis VMAT plan D50 of the PTV changed from 30 Gy to 29.3 Gy. Couch model with uniform electron density of 0.18g/cm3 demonstrated an excellent agreement between measured and TPS computed dose. Conclusion: The treatment couch presence between the patient and beam source significantly alters dose in the patient. Modelling the couch in the Monaco TPS can adequately predict the altered dose distribution.  
Keywords: volumetric-modulated arc therapy, treatment planning system, attenuation, buildup, Couchtop.
Full-Text [PDF 1627 kb]   (1949 Downloads)    
Type of Study: Original Research | Subject: Radiation Biology
Send email to the article author

Add your comments about this article
Your username or Email:

CAPTCHA


XML     Print


Download citation:
BibTeX | RIS | EndNote | Medlars | ProCite | Reference Manager | RefWorks
Send citation to:

Zhang R, Fleckenstein J, Gao Y, Miao M, Chi Z, Bai W. Quantification and modelling of the dosimetric impact of the treatment couch in volumetric modulated arc therapy (VMAT) . Int J Radiat Res 2019; 17 (2) :335-344
URL: http://ijrr.com/article-1-2534-en.html


Rights and permissions
Creative Commons License This work is licensed under a Creative Commons Attribution-NonCommercial 4.0 International License.
Volume 17, Issue 2 (4-2019) Back to browse issues page
International Journal of Radiation Research
Persian site map - English site map - Created in 0.05 seconds with 50 queries by YEKTAWEB 4645