[Home ] [Archive]    
:: Main :: About :: Current Issue :: Archive :: Search :: Submit :: Contact ::
Main Menu
Home::
IJRR Information::
For Authors::
For Reviewers::
Subscription::
News & Events::
Web Mail::
::
Search in website

Advanced Search
..
Receive site information
Enter your Email in the following box to receive the site news and information.
..
ISSN
Hard Copy 2322-3243
Online 2345-4229
..
Online Submission
Now you can send your articles to IJRR office using the article submission system.
..

AWT IMAGE

AWT IMAGE

:: Volume 18, Issue 1 (1-2020) ::
Int J Radiat Res 2020, 18(1): 99-107 Back to browse issues page
Accuracy of empirical formulas in evaluation of neutron dose equivalent inside the 60Co vaults reconstructed for medical linear accelerators
A. Ivković , D. Faj , S. Galić , A.H. Karimi , M. Kasabašić , H. Brkić
Department of Biophysics and Radiology, Faculty of Medicine, J. J. Strossmayer University of Osijek, Croatia , hbrkic@mefos.hr
Abstract:   (3020 Views)
Background: In Southeast Europe medical accelerators are sometimes placed in small vaults originally built for 60Co treatment unit. In order to meet shielding requirements for high energy photon beams, the wall thickness had to be increased. Since the vaults are already limited in size, instead of adding more concrete, materials with high-Z elements were used. Limited vault size and addition of high-Z elements can contribute to the neutron dose equivalent for both medical personnel and patients. Materials and Methods: The most commonly used empirical equations for estimation of neutron dose equivalent at the maze door in the vault are by Kersey and Wu-McGinley. In order to assess accuracy of these equations, Monte Carlo (MC) simulations of various geometrical and compositional changes of vault were conducted. Neutron ambient dose equivalent (H*n(10)) was observed when dimensions of the vault walls were reduced gradually. Results: The empirical equations gave results with reasonable accuracy when vaults were of standard size. When the vault was decreased to the size of the usual 60Co unit vault, the most commonly used equations showed significant difference in results (up to 90%) in comparison to MC simulations. MC simulations showed that introducing different materials in shielding can change the neutron dose equivalent in vicinity of accelerators. Conclusion: For vaults limited in size, new simplified equation for neutron dose equivalent at the maze doors is presented, although performing a MC simulation of the specific vault is suggested.
Keywords: LINAC, vault, Monte Carlo simulations, radiotherapy, neutron ambient dose equivalent.
Full-Text [PDF 1676 kb]   (1185 Downloads)    
Type of Study: Original Research | Subject: Radiation Biology
Send email to the article author

Add your comments about this article
Your username or Email:

CAPTCHA



XML     Print


Download citation:
BibTeX | RIS | EndNote | Medlars | ProCite | Reference Manager | RefWorks
Send citation to:

Ivković A, Faj D, Galić S, Karimi A, Kasabašić M, Brkić H. Accuracy of empirical formulas in evaluation of neutron dose equivalent inside the 60Co vaults reconstructed for medical linear accelerators. Int J Radiat Res 2020; 18 (1) :99-107
URL: http://ijrr.com/article-1-2781-en.html


Rights and permissions
Creative Commons License This work is licensed under a Creative Commons Attribution-NonCommercial 4.0 International License.
Volume 18, Issue 1 (1-2020) Back to browse issues page
International Journal of Radiation Research
Persian site map - English site map - Created in 0.05 seconds with 50 queries by YEKTAWEB 4645