[Home ] [Archive]    
:: Main :: About :: Current Issue :: Archive :: Search :: Submit :: Contact ::
Main Menu
Home::
IJRR Information::
For Authors::
For Reviewers::
Subscription::
News & Events::
Web Mail::
::
Search in website

Advanced Search
..
Receive site information
Enter your Email in the following box to receive the site news and information.
..
ISSN
Hard Copy 2322-3243
Online 2345-4229
..
Online Submission
Now you can send your articles to IJRR office using the article submission system.
..

AWT IMAGE

AWT IMAGE

:: Volume 18, Issue 1 (1-2020) ::
Int J Radiat Res 2020, 18(1): 185-189 Back to browse issues page
A primary study on setting the limit ring in intensity-modulated radiation therapy treatment planning in lung cancer
Y. Fan , G. Qiu , Q. Pan , F. Zhang , S. Luan
Department of Chemoradiotherapy Oncology, The Center Hospital of Qinghe, HeBei, China , docfan888@126.com
Abstract:   (2914 Views)
Background:The influence of the limit ring on the final dose distribution in the design of the lung cancer intensity-modulated radiation therapy (IMRT) plan was studied. Materials and Methods: A total of 20 patients with lung cancer in 2017 were selected. Seven radiation beams were designed for each patient, and the limit ring width (RW) was set at 0.6, 0.8, 1.0, and 1.2 cm, respectively. The distance between the inner diameter of the limit ring and the target area (RD) was set 0.6, 0.8, 1.0, and 1.2 cm, respectively. The other parameters used in the plan were set at the same position. In addition, the conformity index (CI) and homogeneity index (HI) were calculated, and normal tissues were assessed. Results: Under the condition of the same number of radiation beams and the same distance between the limit ring and the target area, the smaller the limit ring, the better the CI of the target area and the less the HI of the target area. When the size of the limit ring was set the same, the closer the limit ring was to the target area, the better the CI of the dose in the target area, and the less the HI of the target area. Conclusions: In central lung cancer, when the target volume is approximately 800 cc, the optimal dose distribution is obtained when the RW is set at 0.8 cm and the RD is set at 0.6 cm.
Keywords: Lung cancer, IMRT, limit ring, CI, HI.
Full-Text [PDF 1419 kb]   (1081 Downloads)    
Type of Study: Technical Note | Subject: Radiation Biology
Send email to the article author

Add your comments about this article
Your username or Email:

CAPTCHA



XML     Print


Download citation:
BibTeX | RIS | EndNote | Medlars | ProCite | Reference Manager | RefWorks
Send citation to:

Fan Y, Qiu G, Pan Q, Zhang F, Luan S. A primary study on setting the limit ring in intensity-modulated radiation therapy treatment planning in lung cancer. Int J Radiat Res 2020; 18 (1) :185-189
URL: http://ijrr.com/article-1-2811-en.html


Rights and permissions
Creative Commons License This work is licensed under a Creative Commons Attribution-NonCommercial 4.0 International License.
Volume 18, Issue 1 (1-2020) Back to browse issues page
International Journal of Radiation Research
Persian site map - English site map - Created in 0.06 seconds with 50 queries by YEKTAWEB 4645