Int J Radiat Res 2008, 6(1): 43-50 Back to browse issues page
Diode calibration for dose determination in total body irradiation
M. Allahverdi , Gh. Geraily , M. Esfehani , A. Sharafi , A. Shirazi
, alahverdi@sina.tums.ac.ir
Abstract:   (15140 Views)
Background: Total Body Irradiation (TBI) is different from standard radiotherapy in many aspects, so it is not easy to predict the delivered dose to the patient under TBI treatment. Diode dosimetry procedures for surface dose reading can help to define variations of the actually delivered dose from the prescribed one. The aim of this study was to describe the measurements made to calibrate diodes in order to implement as a dosimeter for TBI tratment. An algorithm was also proposed based on diode dosimetry in order to determine the midplane dose. Materials and Methods: In this study, four p-type diodes connected to a MULTIDOSE electrometer were implemented as dosimeter. For diode calibration a water phantom with dimension of 30×30×32cm3 along with a 0.6 cc Farmer ion chamber were used. Directional dependence of diodes, the effects of thickness correction factor and complete backscatter factor were studied. Three algorithms, arithmetic, geometric mean and proposed algorithm were used to investigate midplane dose determination in TBI condition. Results: It was found by measurements that the effect of angle incident on diode response was significant and should have been taken into account. Variation in thickness correction factor was found about 0.7%. The accuracy in midplane dose determination in the arithmetic, geometric mean and proposed algorithm was about 3.8, 12.5 and 3.3%, respectively. Conclusion: Diode dosimetry is very useful as a check of midplane dose delivered to patients under TBI treatment. When the calibration and correction factors are carefully determined, high precision can be obtained. The proposed algorithm by this study seems to be useful in order to midplane dose determination in TBI condition. Iran. J. Radiat. Res., 2008 6 (1): 43-50
Keywords: Diode calibration, total body irradiation.
Full-Text [PDF 431 kb]   (4815 Downloads)    
Type of Study: Original Research | Subject: Radiation Biology
Send email to the article author

Add your comments about this article
Your username or Email:

CAPTCHA


XML     Print


Download citation:
BibTeX | RIS | EndNote | Medlars | ProCite | Reference Manager | RefWorks
Send citation to:

Allahverdi M, Geraily G, Esfehani M, Sharafi A, Shirazi A. Diode calibration for dose determination in total body irradiation. Int J Radiat Res 2008; 6 (1) :43-50
URL: http://ijrr.com/article-1-378-en.html


Rights and permissions
Creative Commons License This work is licensed under a Creative Commons Attribution-NonCommercial 4.0 International License.
Volume 6, Issue 1 (6-2008) Back to browse issues page
International Journal of Radiation Research
Persian site map - English site map - Created in 3.11 seconds with 50 queries by YEKTAWEB 4645