Scatter radiation dose profile evaluation in computed tomography using Monte Carlo simulation
Gh.R. Fallah Mohammadi , L. Hesamnezhad , M. Mahdavi
Department of Radiology, Faculty of Allied Medicine, Mazandaran University of Medical Sciences, Sari, Iran , gh.fallah@mazums.ac.ir
Abstract:   (2114 Views)
Background: Conventional radiation dosimetry methods in computed tomography (CT) are not able to measure the dose distribution along the patient’s longitudinal axis. To calculate the dose index on a CT scan, the dose distribution from the center of the radiation field must be calculated. In this study, the most appropriate integral interval for calculating the CT dose index in the axial mode was determined using the Monte Carlo (MC) method based on X-ray photon energy and slice thickness. Materials and Methods: The computed tomography dose index (CTDI) phantom was simulated in the EGSnrc/BEAMnrcMC system and was irradiated with several X-ray energies and several slice thicknesses and dose profiles in phantom were investigated. The area under the dose profile and the scatter to primary radiation dose ratio (SPR) were calculated. Results: The range of scattered beams from the center of the radiation field reaches 450 mm in 140 kV and a 40 mm slice thickness. The SPR value for all levels of X-ray photon energy (between 80 and 140 kV) significantly decreases as slice thickness increases. CT scan imaging technical factors greater than 310 mm from the center of the slice thickness have no effect on the behavior of the scattered radiation. Conclusion: The primary beams are more affected by the energy of the photons, and the scatter beams are more strongly affected by the slice thickness. For 64-slice scanners, the polymethyl methacrylate (PMMA) phantom length should be between 700 mm and 900 mm to yield accurate CTDI estimations.
Keywords: Dose profile, CT scan, scatter radiation, CTDI phantom, MC simulation.
Full-Text [PDF 1663 kb]   (1131 Downloads)    
Type of Study: Original Research | Subject: Radiation Biology
Send email to the article author

Add your comments about this article
Your username or Email:

CAPTCHA



XML     Print


Download citation:
BibTeX | RIS | EndNote | Medlars | ProCite | Reference Manager | RefWorks
Send citation to:

Fallah Mohammadi G, Hesamnezhad L, Mahdavi M. Scatter radiation dose profile evaluation in computed tomography using Monte Carlo simulation. Int J Radiat Res 2021; 19 (4) :813-818
URL: http://ijrr.com/article-1-3958-en.html


Rights and permissions
Creative Commons License This work is licensed under a Creative Commons Attribution-NonCommercial 4.0 International License.
Volume 19, Issue 4 (10-2021) Back to browse issues page
International Journal of Radiation Research
Persian site map - English site map - Created in 0.07 seconds with 50 queries by YEKTAWEB 4645