:: Volume 9, Issue 3 (12-2011) ::
Int J Radiat Res 2011, 9(3): 145-150 Back to browse issues page
Evaluation of treatment planning system monitor unit calculations for three intensity modulated radiotherapy delivery techniques
M.N. Anjum , W. Parker , I. Aldahlawi , R. Ruo , M. Afzal
, muhammad.anjum@mail.mcgill.ca
Abstract:   (12546 Views)
Background: We have validated the monitor unit calculations from a commercially available treatment planning system (TPS) for three intensity modulated radiotherapy (IMRT) planning techniques for tangential breast irradiation by using ionization chamber measurements. Materials and Methods: Treatment plans were generated for forty-two breast patients by a forward planned field in field technique, electronic tissue compensation (ETC), and an inverse planned sliding window technique. We also performed a reproducibility of delivery and dose linearity analysis for each technique. The treatments were delivered to a phantom using a Varian CL21EX linear accelerator. A 2571 0.6 cm3 Farmer type ionization chamber and Farmer 2570/1 electrometer from NE Technology was used to measure output of the linear accelerator and the dose at predefined point in the verification plan. Results: The agreement between the measured and calculated dose was -0.87% ± 0.54% for field in field technique, -0.74% ± 0.23% for electronic tissue compensators, and -1.26% ± 0.48% for the inverse planning technique and. In terms of reproducibility the mean deviation was -1.10% ± 0.44% for the field in field technique, -0.38% ± 0.42% for electronic tissue compensators, -1.04% ± 0.42% for inverse planning technique. Dose linearity experiments showed no significant variations for clinical situations but a breakdown was observed in relative dose for very low monitor units. Conclusion: We have found that the monitor unit calculations for all three planning techniques are correct to the order of 1%, and that the plans can be delivered in a reproducible and accurate manner. Iran. J. Radiat. Res., 2011 9(3): 145-150
Keywords: IMRT QA, dose delivery system, dose calculation accuracy, electronic tissue compensators, reproducibility, dose linearity
Full-Text [PDF 335 kb]   (4652 Downloads)    
Type of Study: Original Research | Subject: Radiation Biology
Send email to the article author

Add your comments about this article
Your username or Email:

CAPTCHA


XML     Print


Download citation:
BibTeX | RIS | EndNote | Medlars | ProCite | Reference Manager | RefWorks
Send citation to:

Anjum M, Parker W, Aldahlawi I, Ruo R, Afzal M. Evaluation of treatment planning system monitor unit calculations for three intensity modulated radiotherapy delivery techniques. Int J Radiat Res 2011; 9 (3) :145-150
URL: http://ijrr.com/article-1-800-en.html


Rights and permissions
Creative Commons License This work is licensed under a Creative Commons Attribution-NonCommercial 4.0 International License.
Volume 9, Issue 3 (12-2011) Back to browse issues page
International Journal of Radiation Research
Persian site map - English site map - Created in 0.05 seconds with 50 queries by YEKTAWEB 4660