[Home ] [Archive]    
:: Main :: About :: Current Issue :: Archive :: Search :: Submit :: Contact ::
Main Menu
Home::
IJRR Information::
For Authors::
For Reviewers::
Subscription::
News & Events::
Web Mail::
::
Search in website

Advanced Search
..
Receive site information
Enter your Email in the following box to receive the site news and information.
..
ISSN
Hard Copy 2322-3243
Online 2345-4229
..
Online Submission
Now you can send your articles to IJRR office using the article submission system.
..

AWT IMAGE

AWT IMAGE

:: Volume 12, Issue 3 (7-2014) ::
Int J Radiat Res 2014, 12(3): 257-264 Back to browse issues page
A quality assurance program for an amorphous silicon electronic portal imaging device using in-house developed phantoms: a method development for dosimetry purposes
A. Jomehzadeh , P. Shokrani , M. Mohammadi , A. Amouheidari
Medical Physics Department, Isfahan University of Medical Sciences, Isfahan, Iran , jomehzadeh@rums.ac.ir
Abstract:   (7694 Views)

Background: Electronic portal imaging devices (EPIDs) play an important role in radiation therapy portal imaging, geometric and dosimetric verifications. A successful utilization of EPIDs for imaging and dosimetric purposes requires a reliable quality control process routine to be carried out regularly. In this study, two in-house phantoms were developed and analyzed for implementation in a quality assurance program for dosimetry purposes. Materials and Methods: An amorphous silicon (a-Si) imager (OptiVue500) was used. A low contrast resolution phantom and an image quality phantom were constructed and implemented. Low contrast resolution of the EPID was evaluated by counting the number of holes detectable in the image of phantom using human observers and a software. The image quality phantom was used for modulation transfer function, contrast to noise ratio and noise level evaluations. This phantom contains five sets of high-contrast rectangular bar patterns of variable spatial frequencies and six uniform regions. Results: Although the manual low contrast resolution method was observer-dependent and insensitive to artifacts, the automatic method was robust and fully objective but sensitive to artifacts. The critical frequency values for 6 and 18 MV were 0.3558±0.006 lp/mm and 0.2707±0.006 lp/mm respectively. The contrast-to-noise ratio was found to be ~ 240% higher for 6 MV compared to 18 MV. Conclusion: The developed phantoms provide a convenient process for periodic performance of an EPID. These phantoms are independent of the EPID system and provide robust tools for continuous monitoring of image quality parameters as well as dosimetric parameters.

Keywords: Electronic portal imaging device, quality assurance, phantom
Full-Text [PDF 942 kb]   (4531 Downloads)    
Type of Study: Original Research | Subject: Medical Physics
Send email to the article author

Add your comments about this article
Your username or Email:

CAPTCHA


XML     Print


Download citation:
BibTeX | RIS | EndNote | Medlars | ProCite | Reference Manager | RefWorks
Send citation to:

Jomehzadeh A, Shokrani P, Mohammadi M, Amouheidari A. A quality assurance program for an amorphous silicon electronic portal imaging device using in-house developed phantoms: a method development for dosimetry purposes . Int J Radiat Res 2014; 12 (3) :257-264
URL: http://ijrr.com/article-1-1284-en.html


Rights and permissions
Creative Commons License This work is licensed under a Creative Commons Attribution-NonCommercial 4.0 International License.
Volume 12, Issue 3 (7-2014) Back to browse issues page
International Journal of Radiation Research
Persian site map - English site map - Created in 0.05 seconds with 50 queries by YEKTAWEB 4645